Recommendations For The Customer-Supplied Cable - Schneeberger MINISCALE PLUS Manual

The unique miniature guideway with integrated measuring system and a resolution of 0.1 mm
Table of Contents

Advertisement

6
Output Signals and Supply
6.4

Recommendations for the Customer-Supplied Cable

24
Sold & Serviced By:
www.servo2go.com
Toll Free Phone: 877-378-0240
Toll Free Fax: 877-378-0249
sales@servo2go.com
sales@servo2go.com
www.servo2go.com
www.servo2go.com
The flexible printed circuit board between the sensor and the interface module can
only be used statically. The bending radius of the flexible printed circuit board must
not fall below 2 mm. The dynamic movements must be managed by a customer-
supplied cable.
• In order to ensure maximum resistance to interference, a shielded twisted pair
cable is recommended. A cable with additional shielding should be used if
necessary.
• Suitable shielding must be ensured in any case.
• The cable shielding must not act as a potential equalization conductor.
• Place the encoder cable apart from the power cables and ensure that the two
are not parallel.
• If the cable is to be run through a cable carrier, a flexible cable that is suitable for
this purpose should be used.
• Keep the cable short
• The cable length between the interface module and the controller should not
exceed 30 meters.
• The maximum cable length is reduced when increasing speeds (above 1.2 m/s)
in connection with the digital interface module.
35
30
25
20
15
10
5
0
0.1
Example: For a maximum speed of 3.2 m/s with the digital interface module, the
data rate is 8 MHz. This corresponds to a maximum cable length of 15 meters.
• Bus termination resistors for RS 422 should be 120 Ohms.