5
Installation and Adjustment Guidelines
Toll Free Phone: 877-378-0240
Toll Free Fax: 877-378-0249
sales@servo2go.com
sales@servo2go.com
www.servo2go.com
www.servo2go.com
5.8.3
Connecting to the Interface Module
These installation instructions are not a guide on ESD but are simply to give an
overview of how MINISCALE PLUS should be operated.
An ESD wrist strap with ground cable or crocodile clamps on the machine bed
acting as such should be used as a minimum when installing MINISCALE PLUS.
Provided the MINISCALE PLUS flexible printed circuit board is in the ESD-protec-
tive packaging, no ESD protection or wrist strap is necessary.
The ESD-protective packaging should not be removed during installation of the
guideway so that the sensor remains protected.
The ESD-protective packaging can only be removed once MINISCALE PLUS is
grounded on the machine bed and the person is properly protected from ESD
(e.g. by wearing an grounded wrist strap).
Remove tape (L)
L
The flexible printed circuit board (C) must not be damaged during removal of the
protective packaging.
C
After the protective packaging has been removed, MINISCALE PLUS is unprotect-
ed and must only be touched by ESD-protected persons.