Schneeberger MINISCALE PLUS Manual page 18

The unique miniature guideway with integrated measuring system and a resolution of 0.1 mm
Table of Contents

Advertisement

6
Output Signals and Supply
18
Sold & Serviced By:
www.servo2go.com
Toll Free Phone: 877-378-0240
Toll Free Fax: 877-378-0249
sales@servo2go.com
sales@servo2go.com
www.servo2go.com
www.servo2go.com
6.2.2
Signaling
In order to increase the resistance to interference, transmitting the signals in an
interpolated form is recommended. Transmitting signals in opposite phases
symmetrically can almost entirely prevent interference. The amplitude of the
differentially transmitted signals equates to 1V
For single-ended signaling, the voltage changes relative to a reference potential.
The amplitude of such a signal amounts to 0.5 V.
This interface works with all standard controllers that support a 1 V
interface.
6.2.3
Pin allocation for analog interface module 1V
Interface module:
Male 9-pin D-sub connector.
Customer-supplied cable: Female 9-pin D-sub connector
Pin
Signal
1
Ua1 -
2
GND
3
Ua2 -
4
ERR NOT
5
Ua0 -
6
Ua1 +
7
+5V DC
8
Ua2 +
9
Ua0 +
6.2.4
Function Check
The green LED will light up if the MINISCALE PLUS is correctly supplied with
power.
Interface module without MINISCALE PLUS flexible
printed circuit board. Both the green and red LEDs
light up
.
SS
SS
Signal type
Sine-
Supply voltage
Cosine-
Error signal
Reference signal -
Sine +
Supply voltage
Cosine +
Reference signal +
Interface module with correctly connected
MINISCALE PLUS flexible printed circuit board.
The green LED lights up
voltage
SS
(IM SCPA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Minirail

Table of Contents