Schneeberger MINISCALE PLUS Manual page 23

The unique miniature guideway with integrated measuring system and a resolution of 0.1 mm
Table of Contents

Advertisement

6
Output Signals and Supply
PC software for USB counter 026
2-axis SIRIUS II position indicator
SIRIUS llr
Interpolation
Digital TTL input
(4-edge evaluation)
Sold & Serviced By:
www.servo2go.com
Toll Free Phone: 877-378-0240
Toll Free Fax: 877-378-0249
sales@servo2go.com
sales@servo2go.com
www.servo2go.com
www.servo2go.com
• For operating the USB counter, PC software for demonstrating the functionality
is available.
• A DLL file is available for customers that wish to write their own software
applications.
6.3.6
Using the digital interface module with the digital 2-axis SIRIUS II
position indicator (for technical information, see chapter 12 in the
MINI-X product catalogue).
Storage temperature of the position indicator:
-40 °C to + 70 °C
Operating temperature of the position indicator:
0 °C to 45 °C in relative humidity between 15% and 95% without condensation.
Digital signal input to the position indicator must be used in order to make use of
the full resolution of the interface module in the position indicator. This has a
maximum permissible input frequency of 1 MHz (based on one channel, e.g. the A
signal). Consequently, a count rate around 4 times higher occurs during 4-edge
evaluation. This limits the maximum possible travelling speed to 0.4 m/s for a
resolution of 0.1 µm.
Resolution
Input frequency
0.1 μm
1 MHz
The configuration menu must be set as follows:
Name
x
Reference mode
once
Direction
positive
Counting direction
-
Signal period
100 µm
Interpolation
1000 times
Spacing
0 mm
Start point
0 mm
Base
-
Increment
0.0001 mm
Increment
0.0001 inch
Speed
Max. 0.4 m/s