Cleaning Valves - Graco Uniblock Series Instructions Manual

Usp progressive valve for oil and grease lubrication
Table of Contents

Advertisement

Installation
Blockages
Blocks require a higher than normal pumping pressure.
Depending on the application or system design, this
blockage will usually result in a complete loss of lubri-
cant flow into the total system and no bearing will be
receiving lubrication.
The loss of flow due to a blockage is first indicated with
the higher than normal system pressure that is devel-
oped by the pump as it attempts to overcome this block-
age. Higher pressure is limited, isolated and signaled
through the use of various performance indicators, reset
and relief, incorporated into the system design. Contact
your Graco distributor for available parts.

Cleaning Valves

NOTICE
• Dirt and foreign material will damage lubricating
equipment. Perform all service and disassembly
under the cleanest possible conditions.
• Hard or sharp metal objects such as punches,
screwdrivers, and picks can scratch and damage
piston bore. When cleaning these surfaces use a
brass rod and hand pressure only.
1. Remove end plugs only and try to move each piston
back and forth without removing the piston from the
valve section.
If all pistons move freely and there is no indication
of a more serious problem:
2. Replace end plugs.
Contamination Blockage
If dirt, foreign material or any other form of contamina-
tion is found in a valve, cleaning that valve will only tem-
porarily solve contamination blockage problems. The
source of the contamination must be eliminated for sat-
isfactory service.
The system filtering method must be investigated, filter
elements should be inspected and cleaned if necessary.
The reservoir filling method should be reviewed to elimi-
nate any chance of foreign material entering the reser-
voir during filling.
6
Separation Blockage
If a hard wax or soap-like material is found in the Valve
Section, grease separation is occurring. This means that
the oil is being squeezed from the grease at normal sys-
tem operating pressure and the grease thickener is
being deposited in the divider valve. Cleaning the divider
valve will only temporarily solve the problem. Consult
your lubricant supplier for recommendations on alter-
nate lubricants and your local Graco distributor to verify
compatibility with centralized lubricating systems.