Summary of Contents for REVENT RVL50

  • Page 1 English models RVL50, RVL70, RVL80, RVL90, RVL110, RVL130, RVL150 Installation Guide Read and Save These Instructions Need Help? Watch the installation video at: reventfans.com/install Questions? Call 1-877-543-8698 (English) or 1-800-615-5439 (French)
  • Page 2: Specifications

    Care And Cleaning page 20 ..... Frequently Asked Questions page 21 ..... 3-Year Limited Warranty Specifications RVL50, RVL70, RVL80 Duct Exhaust Diameter 4 in ( 10.2 cm ) Voltage 120 V Frequency 60 Hz Fan Watts 13 W, 16 W, 20 W...
  • Page 3 RVL90, RVL110 Duct Exhaust Diameter 4 in ( 10.2 cm ) Voltage 120 V Frequency 60 Hz Fan Watts 23 W, 30 W LED Watts 13 W LED Brightness 900, 1000, or 1000 Lumens LED Color Temp 2700, 4000, or 5000 Kelvin Air Flow 90 CFM, 110 CFM Fan Weight...
  • Page 4: What's Inside The Box

    What’s Inside The Box SHIELD DAMPER Qty:1 Qty:1 Qty:1 English models RVL50, RVL70, RVL80, RVL90, RVL110, RVL130, RVL150 Installation Guide Read and Save These Instructions Need Help? Watch the installation video at: reventfans.com/install Questions? Call 1-877-543-8698 (English) or 1-800-615-5439 (French)
  • Page 5: Safety Information

    Safety Information 1.) WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 6: Planning Your Installation

    Planning Your Installation When installing the ventilation fan in a new construction site, install the main body of the FAN and duct work during the rough-in construction of the building. The SHIELD should be installed after the finished ceiling is in place. When installing in existing construction, use the provided cutout TEMPLATE for the ceiling.
  • Page 7: Connecting The Duct

    Fans installed with existing ducts may not achieve their ● rated airflow. ● For models RVL50, RVL70, RVL80, RVL90, or RVL110, 4 in (10.16 cm) round is ● recommended for best performance. For models RVL130 or RVL150, ●...
  • Page 8: Removing Your Old Fan

    Removing Your Old Fan 1.) Disconnect the electrical power supply and lock out the service panel for the existing fan. 2.) Remove the grille from the existing fan. Pull the grille down to expose it’s two springs. Squeeze each spring together and pull down again to release the springs from the motor plate slots.
  • Page 9 SheetLock Easy Roomside ® Installation Watch the video: REVENTFANS.COM/INSTALL WARNING: Disconnect all AC Power Breakers or Fuses before attempting to cut into your ceiling. 1.) Place the provided sheetrock cutout TEMPLATE on ceiling where you wish the FAN to be (DAMPER and electrical positions shown on TEMPLATE). We suggest using painter’s masking tape to hold the template in place while cutting.
  • Page 10: Fan Damper

    3.) Attach DAMPER to ducting. Tape DAMPER to ducting with duct tape. Set the connected DAMPER and ducting in the ceiling opening, then set the FAN in the ceiling opening as well. Connect DAMPER and ducting with duct tape ducting DAMPER Place FAN and DAMPER ceiling...
  • Page 11 WARNING: Disconnect the AC power before any work is done to any part of the circuit ReVent is connected to. If you do not understand this warning, seek the services of a qualified licensed electrician. WARNING: Copper to copper only. Do not use aluminum wire.
  • Page 12 10.) Connect wiring using the provided QUICK CONNECTS (U.S.A.) or WIRE NUTS (Canada). 2-WIRE QUICK 4-WIRE QUICK WIRE NUT CONNECT CONNECT Qty:4 Qty:2 Qty:3 (Canada only) (U.S.A. only) (U.S.A. only) Wire connection for fan and light on separate switches: line line line in line in...
  • Page 13 SWITCHES NOT INCLUDED, USE EXISTING OR MUST BE PURCHASED SEPARATELY Always follow all safety instructions included with the switch you purchase. Do not exceed maximum electrical ratings. ReVent ® light white ground white black black fan switch light switch (purchased separately)
  • Page 14 12.) Press and bend the final securing tabs flat against ceiling to lock the FAN in place. final securing tabs apply even sheetrock pressure to (ceiling) each side of securing tab 13.) Align TRIM RING notch to vent (DAMPER) position. Attach TRIM RING to FAN.
  • Page 15 Construction Framing NOTE: Even with new construction, you can use the SheetLock installation ® method; however, ReVent can still be installed using a method home ® builders would be more familiar with, as outlined in this section. WARNING: Disconnect all AC Power Breakers or Fuses before attempting to cut into your ceiling.
  • Page 16 3.) Attach FAN to ceiling joists with BRACKETS using ROUNDHEAD WOOD SCREWS, then install the sheetrock for your ceiling. conduit ducting SHORT BRACKET (can be cut down) framing joist framing joist SHORT LONG BRACKET BRACKET ROUNDHEAD WOOD SCREW #8 x "...
  • Page 17 WARNING: Disconnect the AC power before any work is done to any part of the circuit ReVent is connected to. If you do not understand this warning, seek the services of a qualified licensed electrician. WARNING: Copper to copper only. Do not use aluminum wire.
  • Page 18 SWITCHES NOT INCLUDED, MUST BE PURCHASED SEPARATELY Always follow all safety instructions included with the switch you purchase. Do not exceed maximum electrical ratings. ReVent ® light white ground white black black fan switch...
  • Page 19 8.) Once connected, reattach the electrical enclosure. slide plug in fan connectors reattach set screw 9.) P ress and bend the final securing tabs flat against ceiling to lock the FAN in place. final securing tabs apply even sheetrock pressure to (ceiling) each side of securing tab...
  • Page 20: Care And Cleaning

    11.) Select desired LED color temperature by sliding the selector switch on the back of the SHIELD. warm white (2700K) SHIELD bright white (4000K) daylight (5000K) 12.) Connect LED wire to LED plug. Attach the SHIELD by squeezing the mounting springs together and inserting the springs into the spring guides in the FAN.
  • Page 21: Frequently Asked Questions

    Q: Can I install my bathroom ventilation FAN directly over a bathtub or shower? A: Yes, but your FAN must be rated for over a shower/bath installation (all ReVent models are) and must be on a GFCI protected circuit. Consult a qualified licensed electrician about ground fault protected safety circuits.
  • Page 22: Year Limited Warranty

    GTR Technologies Inc. www.reventfans.com Need Help? Watch the installation video at: reventfans.com/install Questions? Call 1-877-543-8698 (English) or 1-800-615-5439 (French) info@reventfans.com ReVent is a product of GTR Technologies Inc. All rights reserved. ® USA and international patents pending. PART# RVP-120-WH-05 062320...