How to connect wiring to the terminal
■ For stranded wiring
(1) Cut the wire end with cutting pliers, then strip the insulation
to expose the stranded wiring about 10 mm and
tightly twist the wire ends.
Stranded wire
(2) Using a Phillips head screwdriver, remove the terminal
screw(s) on the terminal board.
(3) Using a ring connector fastener or pliers, securely clamp
each stripped wire end with a ring pressure terminal.
(4) Place the ring pressure terminal, and replace and tighten
the removed terminal screw using a screwdriver.
Special
Screw
washer
Ring pressure
terminal
Terminal board
Wire
■ Wiring
Type T2
Functional ground screw (Schedule Timer)
Power cable
Protective ground screw
Earth Wiring : Make the earth
wiring 25 - 30 mm longer than
power cable.
How to carry out power supply wiring
(1) Wiring connection ports
The power inlet port is located at the rear.
The remote control wiring inlet port is located at the rear (for use with the wired remote controller). For details, see the figure under the
section 3-1 (3).
(2) How to carry out wiring
● Insert the power wiring into the indoor unit through the rubber at the side of the electrical component box.
● For wiring connection to the outdoor unit and remote control wiring, open the elongated hole of the piping cover and pass the wires
through the hole.
NOT E
Be sure to use sealing putty to seal off the opening to prevent dust.
Ring
pressure
terminal
Screw and
Special washer
Ring
pressure
terminal
Wire
Clamp
Power wiring
■ Examples of shield wires
(1) Remove cable coat not to scratch braided shield.
(2) Unbraid the braided shield carefully and twist the
unbraided shield wires tightly together. Insulate the shield
wires by covering them with an insulation tube or wrapping
insulation tape around them.
(3) Remove coat of signal wire.
(4) Attach ring pressure terminals to the signal wires and the
shield wires insulated in Step (2).
Remote Control Wiring
Clamp
Use this screw when connecting the shield for the Inter-unit control wiring to ground.
(
: Functional earthing)
16
Insulation tape
Shield mesh
Insulation tape
Shield mesh
Inter-unit Control Wiring
Remote control wiring and inter-unit control
wiring inlet port
* Insert the remote control wiring and
inter-unit control wiring into the electrical
component box from the inlet port as shown
in the figure. This is done regardless of
whether the wiring was inserted from the
top, rear, or left side of the main unit.