Disk 1:60 Configuration - EMC ATMOS Hardware Manual

Hide thumbs Also See for ATMOS:
Table of Contents

Advertisement

Disk 1:60 Configuration

Symptom
(I) Only 46 to 60 disk drives are 
accessible.
Drive is unavailable.
Drive is reporting faulted 
or is missing in Adaptec 
Storage Manager.
4: Troubleshooting
Probable Cause
Disk drive(s)
Recommended Actions
If one drive is faulty, 
1
physically locate the bad 
drive and replace it.
N
:   To locate drives, 
O T E
look for Amber Fault 
LEDs. If a DAE fault LED 
is on blinking, the fault is 
in the DAE behind the 
blinking enclosure. If a 
DAE fault LED is on solid, 
the failure is in that 
enclosure.
If more than one disk is 
2
faulted, power down the 
server and power cycle the 
DAEs. After DAEs are 
back up, power on the 
server.
If multiple disks still 
3
remain faulted or missing, 
physically locate disks and 
replace them.
Disk 1:60 Configuration
37

Advertisement

Table of Contents
loading

Table of Contents