SIMATIC
ET 200SP HA
Digital Output Module RQ
4x120VDC-230VAC/5A CO HA
(6DL1132-6HD50-0PK0)
Manual
11/2017
A5E39389042-AC
Security information
Product overview
Wiring
Parameters
Displays and interrupts
Technical specifications
Drivers, parameters,
diagnostics messages and
address space
1
2
3
4
5
6
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RQ 4x120VDC-230VAC/5A CO HA

  • Page 1 Security information Product overview Wiring SIMATIC Parameters ET 200SP HA Digital Output Module RQ Displays and interrupts 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Technical specifications Manual Drivers, parameters, diagnostics messages and address space 11/2017 A5E39389042-AC...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Security information............................5 Product overview............................7 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA...........7 Wiring.................................11 Pin assignment of the I/O module RQ 4x120VDC-230VAC/5A CO HA.........11 Schematic circuit diagram......................13 Parameters..............................15 Parameters of the I/O module RQ 4x120VDC-230VAC/5A CO HA........15 Module/channel parameters....................16 Explanation of the module/channel parameters..............17 Displays and interrupts..........................19...
  • Page 4 Table of contents Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 5: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber...
  • Page 6 Security information Conventions Please also observe notes marked as follows: Note A note contains important information on the product described in the documentation, on the handling of the product and on the section of the documentation to which particular attention should be paid.
  • Page 7: Product Overview

    Product overview Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA [ID: 80187982219] View of the module 4x 12 0V DC ..2 30 VA C/ 5A CO DI AG M T 1 .0 1P 1 L+ 24 VD C M 2P 1 L+ 24 1P 2 VD C M...
  • Page 8 Product overview 2.1 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA Properties NOTICE I/O modules with relay contacts ● I/O modules with relay contacts are only suitable for an elevation up to 3000 m (corresponds to air pressure of around 690 hPa). ●...
  • Page 9 Product overview 2.1 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA Accessories The following accessories must be ordered separately: ● Labeling strips ● Color-coded labels ● Reference identification label ● Shield connector Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 10 Product overview 2.1 Properties of the I/O module RQ 4x120VDC-230VAC/5A CO HA Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 11: Wiring

    Wiring Pin assignment of the I/O module RQ 4x120VDC-230VAC/5A CO [ID: 85663030923] Terminal blocks You can operate the I/O module with the following terminal blocks: ● 6DL1193-6TP00-0DK0, light ● 6DL1193-6TP00-0BK0, dark The terminal block is not included in the scope of delivery of the I/O module and must be ordered separately.
  • Page 12 Wiring 3.1 Pin assignment of the I/O module RQ 4x120VDC-230VAC/5A CO HA General pin assignment Table 3-1 Pin assignment of the RQ 4x120VDC-230VAC/5A CO HA Terminal Assignment Terminal Assignment Explanations : Common contact : NO : NC 1P1: Supply voltage L+ of the voltage bus 1P 2P1: Supply voltage L+ of the voltage bus 2P 1P2: Ground reference of the voltage bus 1P 2P2: Ground reference of the voltage bus 2P...
  • Page 13: Schematic Circuit Diagram

    Wiring 3.2 Schematic circuit diagram Schematic circuit diagram [ID: 80188014219] The following figure shows the block diagram of the RQ 4x120VDC-230VAC/5A CO HA. Figure 3-1 Block diagram RQ 4x120VDC-230VAC/5A CO HA Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 14 Wiring 3.2 Schematic circuit diagram Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 15: Parameters

    Parameters Parameters of the I/O module RQ 4x120VDC-230VAC/5A CO HA [ID: 80188111115] Configuring You configure the I/O module with PCS 7 V9.0 or higher. Parameters You define the functioning of the I/O module via parameters. See also Parameter assignment (Page 29) Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 16: Module/Channel Parameters

    Parameters 4.2 Module/channel parameters Module/channel parameters [ID: 91038645131] Parameters of the RQ 4x120VDC-230VAC/5A CO HA You have the following setting options: Table 4-1 Parameters and their default settings Parameter Value range Default Parameter re‐ Efficiency range assignment in Diagnostics, Disabled Module ●...
  • Page 17: Explanation Of The Module/Channel Parameters

    Parameters 4.3 Explanation of the module/channel parameters Explanation of the module/channel parameters [ID: 80188160651] Diagnostics, Missing supply voltage L+ Enabling of the diagnostics for missing or insufficient supply voltage L+. Channel activated Specifies whether a digital output is activated or deactivated. Reaction to CPU STOP Determines the reaction of the digital output to CPU STOP or to failure of communication between the interface module and CPU.
  • Page 18 Parameters 4.3 Explanation of the module/channel parameters Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 19: Displays And Interrupts

    Displays and interrupts Status and error displays of the I/O module RQ 4x120VDC-230VAC/ 5A CO HA [ID: 80188253579] LED displays The following figure shows the LED displays of the I/O module. 4x120VDC..230VAC/5A CO DIAG MT 1P1 LP+ 24VDC M 1P2 2P1 LP+ M 2P2 24VDC...
  • Page 20 Displays and interrupts 5.1 Status and error displays of the I/O module RQ 4x120VDC-230VAC/5A CO HA DIAG LED Table 5-1 Diagnostics display of the DIAG LED DIAG LED Meaning The power supply of the ET 200SP HA is disrupted or switched off Module is not configured.
  • Page 21: Interrupts

    Displays and interrupts 5.2 Interrupts Interrupts [ID: 80188284939] The I/O module supports diagnostics interrupts and maintenance messages. Diagnostics interrupts The I/O module generates a diagnostics interrupt for the following events: ● Channel/component temporarily unavailable ● Parameter assignment error ● Supply voltage missing ●...
  • Page 22 Displays and interrupts 5.2 Interrupts Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 23: Technical Specifications

    Technical specifications [ID: 80188333963] Technical specifications of the RQ 4x120VDC-230VAC/5A CO HA Article number 6DL1132-6HD50-0PK0 General information Product type designation RQ 4x120VDC-230VAC/5A CO HA HW functional status FS01 Firmware version V1.0 ● FW update possible Usable terminal block TB type K0 Color code for module-specific color identifica‐...
  • Page 24 Technical specifications Article number 6DL1132-6HD50-0PK0 ● Current per channel, max. ● Current per module, max. 20 A Total current of the outputs (per module) horizontal installation 20 A – up to 70 °C, max. vertical installation 20 A – up to 60 °C, max. Relay outputs ●...
  • Page 25 Technical specifications Article number 6DL1132-6HD50-0PK0 Isolation tested with 4 200 V DC/1 min, type test ● between channels and backplane bus/ supply voltage 1 500 V DC/1 min, type test ● between backplane bus and supply voltage Ambient conditions Ambient temperature during operation -40 °C;...
  • Page 26: Switching Cycles

    Technical specifications 6.1 Switching cycles Switching cycles [ID: 80188362763] Switching capacity and lifetime of the contacts With an external protective circuit, the contacts will last longer than specified in the table. This table shows the switching capacity and lifetime of the relay contacts: Table 6-1 Switching capacity and lifetime of the relay contacts Resistive load...
  • Page 27: Drivers, Parameters, Diagnostics Messages And Address Space

    Drivers, parameters, diagnostics messages and address space Concept of the driver and diagnostics blocks [ID: 96680281867] Use outside the PCS 7 environment The following information of the appendix relates to the use of the ET 200SP HA outside the PCS 7 environment. If you do not plan to operate outside the PCS 7 environment, you do not need the information in the appendix.
  • Page 28 A.1 Concept of the driver and diagnostics blocks This block concept supports all modules from the list of approved modules. When new Siemens or non-Siemens module types are integrated, the meta-knowledge for the driver generator can be extended by additional XML files (object and action lists).
  • Page 29: Parameter Assignment

    Drivers, parameters, diagnostics messages and address space A.2 Parameter assignment Parameter assignment [ID: 80188477835] Parameter assignment in the user program You can reconfigure individual channels of the module in RUN without this having an effect on the other channels. Changing parameters in RUN The "WRREC"...
  • Page 30 Drivers, parameters, diagnostics messages and address space A.2 Parameter assignment Every parameter data record is checked by the module. If an incorrect parameter is detected, the entire data record is rejected and the parameters of the module remain unchanged. Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 31: Parameter Assignment And Structure Of The Module/Channel Parameters

    Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters Parameter assignment and structure of the module/channel parameters [ID: 91040766603] Structure of data record 128 Data record 128 has a length of 20 bytes. It contains module parameters as well as channel or technology parameters of the 4 channels;...
  • Page 32 Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters Header information and module parameters The following figure shows the structure of the header information and module parameters. Figure A-2 Header information and module parameters of data record 128 Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...
  • Page 33 Drivers, parameters, diagnostics messages and address space A.3 Parameter assignment and structure of the module/channel parameters Channel parameters Each channel parameter block contains the cable parameters for the digital output (2 bytes). The following figure shows the configuration of the channel parameters for data record 128. x = 12 + (channel number * 2);...
  • Page 34: Diagnostics Messages And Maintenance Events

    Drivers, parameters, diagnostics messages and address space A.4 Diagnostics messages and maintenance events Diagnostics messages and maintenance events [ID: 80188307851] Diagnostics messages A diagnostics message is generated for each diagnostics event and the DIAG LED on the RQ 4x120VDC-230VAC/5A CO HA flashes red or the MT LED lights up yellow. The diagnostics messages can be read in the diagnostics buffer of the CPU, for example.
  • Page 35 Drivers, parameters, diagnostics messages and address space A.4 Diagnostics messages and maintenance events Maintenance messages have no direct effect on the function of the module or digital outputs. Table A-2 Maintenance messages, their meaning and possible remedies Maintenance Error code Assignment Meaning / Cause Solution...
  • Page 36: Address Space

    Drivers, parameters, diagnostics messages and address space A.5 Address space Address space [ID: 80188171403] Abbreviations ● "IB" stands for input byte, that is, the module start address in the input area ● "QB" stands for output byte, that is the module start address in the output area ●...
  • Page 37: Index

    Index Properties, 8 Schematic circuit diagram, 13 Technical specifications, 23 Address space, 36 Schematic circuit diagram, 13 Channel fault LED, 19 Channel parameters, 16, 31 Channel status LED, 19 Conventions, 6 Technology parameters, 31 Terminal block, 11 Data record 128, 31 Header information, 32 Value status, 36 DIAG LED, 20...
  • Page 38 Index Digital Output Module RQ 4x120VDC-230VAC/5A CO HA (6DL1132-6HD50-0PK0) Manual, 11/2017, A5E39389042-AC...

This manual is also suitable for:

6dl1132-6hd50-0pk0