Page 1
All necessary components are provided with the kit. External connections to the evaluation kit can be made through the connectors at the edges of the circuit. The circuit provides a line termination of 50 Ω. Figure 1: EK37 Schematic GNDA CL_A...
EK37 BEFORE YOU GET STARTED • All Apex amplifiers should be handled using proper ESD precautions. • Always use the heat sink and thermal washers included in this kit. • Always use adequate power supply bypassing. • Do not change the connections while the circuit is powered •...
Page 5
EK37 Figure 3: Top View 4 X #8 X 0.375" SCREW 4 X #8 X 2.00” HEX STANDOFFS 4 X #4 X 0.187” SCREW 4 X SPACER GROMMETS 4 X #8 X 0.625” SCREW EK37U Rev A...
EK37 TEST ASSEMBLY EQUIPMENT NEEDED 1. Power supply 2. Function Generator 3. Oscilloscope 4. Proper heat sinking system (if operating at high current) TEST SETUP Connect the positive power supply to banana jacks P8 and P17. Since the negative supply is grounded, connect the ground connection of the positive supply to jacks P9 and P16.
Page 8
EK37 Figure 5: Test Results NEED TECHNICAL HELP? CONTACT APEX SUPPORT! For all Apex Microtechnology product questions and inquiries, call toll free 800-546-2739 in North America. For inquiries via email, please contact apex.support@apexanalog.com. International customers can also request support by contacting their local Apex Microtechnology Sales Representative. To find the one nearest to you, go to www.apexanalog.com...