DGC DC-2000C Series Instruction Manual

DGC DC-2000C Series Instruction Manual

Ultrasonic thickness gauge

Advertisement

Quick Links

Ultrasonic Thickness Gauge
DC-2000C series
Instruction Manual
V. 7.11

Advertisement

Table of Contents
loading

Summary of Contents for DGC DC-2000C Series

  • Page 1 Ultrasonic Thickness Gauge DC-2000C series Instruction Manual V. 7.11...
  • Page 2: Table Of Contents

    CONTENTS 1. General Description..................1 2. Technical Specifications................1 3. Standard Delivery..................2 4. Overview the Display Unit................2 5. Keypad Functions..................3 6. Display Screen....................5 7. Preparation before measurement..............5 【7.1】Preparation of the instrument ............5 【7.2】Selection of the Probe ............... 6 【7.3】Treatment of the measured surface ........... 6 8.
  • Page 4: General Description

    (0.01 mm or 0.001 inches) the thickness of metallic and non-metallic materials such as steel, aluminum, titanium, plastics, ceramics, glass and any other good ultrasonic wave conductor. The DC-2000C series accurately displays readings in either inches or millimeters. 2. Technical Specifications :0.65mm~400.0mm...
  • Page 5: Standard Delivery

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE 3. Standard Delivery -- Main Unit 1PC -- Standard 5MHZ probe D5008 1PC -- Couplant 75ML -- AAA batteries (Do not apply) -- Build-in calibration block with 4mm -- Cable (DC-2020C) -- Carrying case 1PC...
  • Page 6: Keypad Functions

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE 5. Keypad Functions DC-2000C On/ Off Key Press this key to switch on or off the instrument. Esc. Menu Press this Key to Escape the Menu. Press This Key to go to the operation Menu.
  • Page 7 DC-2000C SERIES ULTRASONIC THICKNESS GAUGE DC-2020C Press this key to switch on or off the instrument. On/ Off Key Press this Key to Escape the Menu. Esc. Menu Press This Key to go to the operation Menu. Menu Key Press this Key to confirm the selection.
  • Page 8: Display Screen

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE 6. Display Screen ② ① ③ ④ ⑤ ⑧ ⑥ ⑦ ⑨ ① Measurement Value ② Battery Life ③ Measurement Mode ④ Measuring Symbol ⑤ Unit ⑥ Current Probe model ⑦ Current memory location (DC-2020C) ⑧...
  • Page 9: Selection Of The Probe

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE 【7.2】Selection of the Probe Users can select the suitable probe according to the thickness of the workpiece to be measured. Type Freq. Meas. Rang Temp. Application The probe is used common in many measurements, for...
  • Page 10: Basic Operations

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE 8. Basic Operations 【8.1】Switch on Select the probe and insert it into the probe socket and then press switch on the instrument, the screen displays: the Series No. and the version number. If you did not insert the probe before switching on the instrument, the screen will prompt you than “Please insert the probe”, at this moment insert the probe into...
  • Page 11: Parameters Setting

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE 【8.4】Parameters setting 〖8.4.1〗 Measurement There are six measuring modes provided. Users can select different measuring modes according to their requirements and measuring environments. 1. Measurment - Press into - Press to select desired measurment mode.
  • Page 12: Scan (Dc-2020C)

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE limit, it will display and give alarm. This measurement mode is more widely used than differential mode. 8.4.1.6 Scan: (DC-2020C) It is available for measuring the thickness of test piece with high temperature surface. The gauge beeps for each fast measurement. And will display the average measured thickness upon the measurement finished.
  • Page 13: Velocity Measurement

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE materials in the appendix. Take this table to set correct sound velocity for reference. ⑵VEL. input into“ ”, - Press to move the “black arrow”, Press - Press to change the value. - Press to confirm, screen shows 4 locations to store this new velocity,...
  • Page 14: Velocity Storage

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE velocity, press to select one, press to confirm. - Press to Esc. Menu and into the measurment. “2. Velocity This new velocity will be stored. And it can be found from rate”- “⑷Vel. Storage” for further use.
  • Page 15: Memory (Dc-2020C)

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE - Adjust the measured value by pressing and make the test value equal to the actual thickness of test piece. - Press to confirm. The gauge will return to the Measurement mode. 〖8.4.5〗 Memory (DC-2020C) “5.
  • Page 16: Memory Read

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE Notice: Users cannot set location number; it begins as 0000 and plus 1automatically after users store each test result. 8.4.5.2 Memory Read (Under the measurement) into the “Memory Read” function, - Press -Press to set desired Alphabet, Press select location number.
  • Page 17: Switch Off Mode

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE 1. Switch off Mode 2. Gain setting 3. Language 4. Contrast 5. Default 6. Information -Press into the selected item, press to confirm. 8.4.6.1 Switch off mode “6.Function”- “⑴Switch off mode” -Press into the menu - Select Auto shut down after 1 Min.
  • Page 18: Languages

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE 1. High 2. Medium 3. Low 4. Automatic - Press to select desired item - Press to confirm. 8.4.6.3 Languages “6.Function”- “⑶ language” - Press into the Menu - Select desired language - Press to confirm.
  • Page 19: Appendix: Sound Velocity Measurement Chart

    DC-2000C SERIES ULTRASONIC THICKNESS GAUGE APPENDIX: SOUND VELOCITY MEASUREMENT CHART Material Sound Velocity Inch/µS 0.013 Aluminum 6300 0.250 Alumina Oxide 9900 0.390 Beryllium 12900 0.510 Boron Carbide 11000 0.430 Brass 4300 0.170 Cadmium 2800 0.110 Copper 4700 0.180 Glass(crown) 5300 0.210...

This manual is also suitable for:

Dc-2020c

Table of Contents