Download Print this page
Ingersoll-Rand 4WCC4024A1000A Installer's Manual
Ingersoll-Rand 4WCC4024A1000A Installer's Manual

Ingersoll-Rand 4WCC4024A1000A Installer's Manual

Single packaged heat pump 14 seer convertible, 2 - 5 ton

Advertisement

Installer's Guide
Single Packaged Heat Pump
14 SEER Convertible, 2 — 5 Ton
4WCC4024A1000A
4WCC4030A1000A
4WCC4036A1000A
4WCC4042A1000A
4WCC4048A1000A
4WCC4060A1000A
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and
air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered
equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the
literature and on the tags, stickers, and labels that are attached to the equipment.
September 2018
N N o o t t e e : : "Graphics in this document are for representation only. Actual
model may differ in appearance."
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
1 1 8 8 - - E E B B 2 2 9 9 D D 1 1 - - 1 1 F F - - E E N N

Advertisement

loading

Summary of Contents for Ingersoll-Rand 4WCC4024A1000A

  • Page 1 Installer’s Guide Single Packaged Heat Pump 14 SEER Convertible, 2 — 5 Ton 4WCC4024A1000A 4WCC4030A1000A 4WCC4036A1000A 4WCC4042A1000A 4WCC4048A1000A 4WCC4060A1000A N N o o t t e e : : “Graphics in this document are for representation only. Actual model may differ in appearance.”...
  • Page 2 SAFETY SECTION I I m m p p o o r r t t a a n n t t — This document contains a wiring W W A A R R N N I I N N G G diagram, a parts list, and service information.
  • Page 3: Table Of Contents

    Table of Contents Introduction ....... . 4 Step 5 — Unit Startup ..... 20 Step 2 —...
  • Page 4: Introduction

    Introduction Read this manual carefully before attempting to install, operate, or perform maintenance on this unit. 1. Check for damage after the unit is unloaded. Report Installation and maintenance should be performed by promptly to the carrier any damage found to the qualified service technicians only.
  • Page 5: Step 2 - Determine Unit Clearances

    Step 2 — Determine Unit Clearances Figure 1. 2 — 3 TON MODELS The view labeled Bottom Side represents the base as viewed looking up from underneath the unit. 18-EB29D1-1F-EN...
  • Page 6 S S t t e e p p 2 2 — — D D e e t t e e r r m m i i n n e e U U n n i i t t C C l l e e a a r r a a n n c c e e s s Figure 2.
  • Page 7 S S t t e e p p 2 2 — — D D e e t t e e r r m m i i n n e e U U n n i i t t C C l l e e a a r r a a n n c c e e s s Figure 3.
  • Page 8 S S t t e e p p 2 2 — — D D e e t t e e r r m m i i n n e e U U n n i i t t C C l l e e a a r r a a n n c c e e s s Figure 4.
  • Page 9 S S t t e e p p 2 2 — — D D e e t t e e r r m m i i n n e e U U n n i i t t C C l l e e a a r r a a n n c c e e s s Figure 5.
  • Page 10 S S t t e e p p 2 2 — — D D e e t t e e r r m m i i n n e e U U n n i i t t C C l l e e a a r r a a n n c c e e s s Figure 6.
  • Page 11: Step 3 - Review Location And Recommendation Information

    Step 3 — Review Location and Recommendation Information H H o o r r i i z z o o n n t t a a l l A A i i r r f f l l o o w w U U n n i i t t s s 3.
  • Page 12: Step 4 - Unit Installation

    Step 4 — Unit Installation N N o o t t e e : : The factory ships this unit for horizontal weatherproof seal where the duct enters the installation. structure. 5. Do not expose the unit to direct roof water runoff. T T o o I I n n s s t t a a l l l l t t h h e e u u n n i i t t a a t t g g r r o o u u n n d d l l e e v v e e l l : : 6.
  • Page 13 S S t t e e p p 4 4 — — U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n Figure 8.
  • Page 14 S S t t e e p p 4 4 — — U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n Table 1.
  • Page 15 S S t t e e p p 4 4 — — U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n Table 2.
  • Page 16 S S t t e e p p 4 4 — — U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n Table 4.
  • Page 17 S S t t e e p p 4 4 — — U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n D D u u c c t t w w o o r r k k I I n n s s t t a a l l l l a a t t i i o o n n N N o o t t e e : : Do not draw the canvas taut between the solid ducts.
  • Page 18 S S t t e e p p 4 4 — — U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n Table 6.
  • Page 19 S S t t e e p p 4 4 — — U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n Table 10.
  • Page 20: Step 5 - Unit Startup

    Step 5 — Unit Startup P P r r e e - - S S t t a a r r t t Q Q u u i i c c k k C C h h e e c c k k l l i i s s t t After the unit has operated in the cooling mode for a short period of time, install pressure gauges on the ☐...
  • Page 21: Sequence Of Operation

    Sequence of Operation G G e e n n e e r r a a l l power to the “W W ” terminal on the indoor thermostat and to the supplementary heater control circuit. An Operation of the unit heating and cooling cycles is outdoor thermostat may have been added to disallow automatic when the system is in the H H E E A A T T or C C O O O O L L the second stage (if provided) of electric heat above a...
  • Page 22: Maintenance

    S S e e q q u u e e n n c c e e o o f f O O p p e e r r a a t t i i o o n n F F i i n n a a l l I I n n s s t t a a l l l l a a t t i i o o n n C C h h e e c c k k l l i i s s t t If the unit has disposable-type filters, replace them with new filters of the same type and size.
  • Page 23: Important Product Information

    S S e e q q u u e e n n c c e e o o f f O O p p e e r r a a t t i i o o n n Important Product Information Packaged Unit Serial Number_____________________________________________________ Packaged Unit Model Number_____________________________________________________ Date of Installation_______________________________________________________________...
  • Page 24 Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands — including Club Car ® , Ingersoll Rand ® , Thermo King ® Trane ® — work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables;...