3.2. Installation

The diagrams below show examples of BEKOMAT
NOTICE
Installation instructions
E
BEKOMAT
8/9
®
8/9 installation options.
®
Install a separate BEKOMAT
Do not use cone-shaped fittings.
Keep the pipes as short as possible.
Do not install filters/dirt traps in the condensate inlet.
Only install ball valves in the condensate inlet line.
The venting line must be installed above the highest possible condensate level.
Observe the minimum installation heights.
Installation of BEKOMAT
A
B
at each point where condensate might be produced.
®
8/9
®
Venting line A:
Lines ≥ ¾" must be equipped with ball valve
Condensate inlet B:
Pipes ≥ 2" (DN 50) must be installed with flange and ball
valve:
short inlet pipe!
Condensate inlet slope >1%!
No filter in condensate inlet!
Condensate discharge C:
Install pipe ≥1"
(for BEKOMAT
Do not feed to a manifold!
Max. incline 5 m!
C
If the pipe is installed at an incline, the minimum
operating pressure is increased by 0.1 bar per metre!
For maintenance:
Manual drain D:
Lines ≥ ¾" must be equipped with ball valve
Bypass line E:
Lines ≥ 1" must be equipped with ball valve
D
Installation and operating manual
9: ≥ 2"):
®