Installation and operating manual

5. Operation

The operating state of the BEKOMAT
Normal status:
Error status:
Alarm status:
18
is indicated as follows.
®
Normal operation:
Green "POWER" LED is lit:
Power OK, BEKOMAT
Yellow "VALVE" LED is lit:
Max. filling level reached
 Valve opens,
condensate is discharged
The valve opening time is sensor-controlled (based on the actual discharge rate)
After condensate has been discharged:
- BEKOMAT
is empty
®
- Valve closes
- No unnecessary compressed air loss
ALARM:
• Insufficient pressure to open valve
• Too much condensate being produced
 see "Technical data"
• Inlet or drain pipe blocked or closed
• Excessive dirt (valve blocked)
• Solenoid valve defective
 see "Maintenance"
• Piping frozen
• Incorrect installation
 see "Installation"
The alarm is automatically reset when the problem that has caused it is resolved.
in operation
®
EN
BEKOMAT
8/9
®