PP(T)70EHC, TRIPHASEE (200V ~3 60Hz)
DISJONCTEUR
COMP 2
5
6 (N/F)
3
4 (N/F)
1
2 (N/F)
DISJONCTEUR
(COMP 1)
5
6 (N/F)
3
4 (N/F)
1
2 (N/F)
18 (N/O)
(COM) 15
16 (N/F)
A1
A2
TEMPORISATION T2
(6 MINS)
TEMPORISATION T1
(12 HEURES)
A1
A2
RELAIS (R2)
18 (N/O)
(COM) 15
A1
16 (N/F)
(N/O) 11
H (N/O)
(N/F) L
THERMOSTAT
DEGIVRAGE
(SE COUPE A H EN
(COM) C
BASSE TEMPERATURE
VOYANT
TEMP OK
VOYANT
ALIMENTATION
PRINCIPALE
DEMARRAGE AMORTI
DISJONCTEUR THERMIQUE
ET VOYANT DEFAUT
SI INSTALLE
DEMARREUR OU
CONTACTEUR DE DEBIT
PRESSOSTAT BP
(SE COUPE A H EN
BASSE PRESSION)
PRESSOSTAT HP
(SE COUPE A L EN
HAUTE PRESSION)
PROTECTION THERMIQUE
VENTILATEUR
PROTECTION ELECTRONIQUE
COMPRESSEUR 2
PROTECTION ELECTRONIQUE
COMPRESSEUR 1
CONTACT ALARME
DISJONCTEUR VENTILATEUR
CONTACT ALARME DISJONCTEUR
COMPRESSEUR 1
CONTACT ALARME DISJONCTEUR
COMPRESSEUR 2
L3
5
6 (N/F)
3
4 (N/F)
L2
2 (N/F)
1
L1
MONITEUR
DISJONCTEUR
L3 L2 L1
DE PHASES
COMMANDE
SD566250 ISSUE 35
CONTACTEUR
(COMP 2)
5
6 (N/O)
(W)
COMP
3
4 (N/O)
(V)
1
2 (N/O)
(U)
21
22 (N/F)
A1
A2
TEMPORISATION T3
CONTACTEUR
(N/O)
(COMP 1)
6 (N/O)
(10 SECS)
5
(W)
COMP
4 (N/O)
3
(V)
2 (N/O)
1
(U)
21
22 (N/F)
A1
A2
A2
COMP 1 MCB AUX
COMP 2 MCB AUX
54
53 (N/O)
14 (COM)
54
53 (N/O)
VOYANT
DEGIVRAGE
DISJONCTEUR
(VENTILATEUR)
CONTACTEUR
(VENTILATEUR)
5
6 (N/F)
5
6 (N/O)
3
4 (N/F)
3
4 (N/O)
1
2 (N/F)
1
2 (N/O)
A1
A2
VOYANT
REFROIDISSEMENT
B
RELAIS (R1)
A
VOYANT
D'INVERSION
CHAUFFAGE
(N/F) L
H (N/O)
PRESSOSTAT ET VOYANT
C (COM)
LIMITE DE
REFROIDISSEMENT
(SE COUPE A H EN BASSE
DE TEMPERATURE)
THERMOSTAT 2 CANAUX
CONTACT 7 ET 8 FERMES EN MODE FROID
OUT 2
CONTACT 6 ET 4 FERMES EN MODE CHAUD
(N/F) L
H (N/O)
COMMUTATEUR
C (COM)
VEILLE
(N/O) L
H (N/F)
C (COM)
TK
(NF)
TK
(N/F)
(N/F)
96 (N/F)
95
44 (N/F)
VOYANT DEFAUT
43
43 (N/F)
44
DISJONCTEUR COMP 1
AUX
13
14 (N/O)
12 (N/F)
11 (COM)
13
14 (N/O)
DISJONCTEUR COMP 2
AUX
2
1
VALEURS DISJONCTEUR
COMPRESSEUR
CIRCUIT
2.5A
MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS
SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON
CONDITION
WATER FLOW SWITCH CONTACTS SHOWN WITH WATER FLOW AT
MAXIMUM RATE
ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH
REFRIGERATION CIRCUIT FULLY CHARGED
WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM
ABOVE CONDITIONS APPLY
VENTILATEUR
SOUPAPE
10
SONDE
11
VOYANT
DEBIT D'EAU
B
RELAIS (R3)
A
COMMUTATEUR
DEBIT D'EAU
(N/O)
ELECTROVANNE
(ARRET LIGNE
LIQUIDE)
VENTILATEUR
32.8A
4.5A
21