7. Maintenance

Changing the microfiber stripes
To change the microfiber stripes, remove the upper arm of
the cleaning and vacuum assembly by loosening the side-
mounted hex screw, then pulling the upper arm gently
upwards.
Next, release the microfiber supporters from the upper and
lower cleaning arms by applying a light pressure at the end of
each microfiber supporter, and then remove them
(see Pic. 4).
Now peel the old microfiber strips away from their supporters.
Before attaching new microfiber strips, it is important to
ensure that any grease, dust or residual glue from the old
microfiber strips is removed from the microfiber supporter.
Apply new microfiber strips, firmly pressing them onto the supporters.
We recommend changing the microfiber strips after approx. 100 cleaning programs, though this will
depend on the condition of the records cleaned.
Cleaning and draining the waste fluid tank
Over time it is possible for residue to settle in the waste fluid tank which could potentially block the
drain tube. To avoid this happening you should periodically clean the waste fluid tank.
1. Remove the upper suction arm after loosening the side-mounted screw with the delivered hex
wrench (#5) and pulling it gently and steadily upwards.
2. Place the filling funnel into the suction tube.
3. To flush the waste tank, we recommend 250ml warm water, which you pour in the waste tank.
4. Let the warm water sit in the waste tank for approximately 20 minutes, then drain it by removing
the sealing plug from the drain hose and put the end of the drain hose into a bowl (etc.) which
is positioned deeper. Repeat this process until the drained flushing water is clean and does not
contain any reside.
After the cleaning, you can remount the suction arm. Please make sure to insert the arm
straight and w ithout any pressure. Otherw ise the arm may tilt and damage the machine.
Please note:
I f you take the machine into operation again, the drain tube must alw ays be closed by
the stopper, so that the vacuum pump can generate the required vacuum for suction.
Only through this w e can guarantee a lasting and full function of your cleaning machine.
The drain tube at the rear should not be pusehd back into the machine. This could bend
the tube and the leaking fluid could damage the cleaning machine.
Made in Germany