Introduction

The remote digital operator kit allows a digital operator to be mounted up to 3 meters from the GPD305/J7. The
kit includes:
1. One remote operator interface attachment
2. One gasket
3. One Digital Operator membrane cover
4. Four screws & nuts
5. Eight rubber washers
6. One RS-232 remote operator interface
7. One cable either 1 meter (DS031) or 3 meter (DS033) in length.

Hardware Installation

HAZARDOUS VOLTAGE CAN CAUSE SEVERE INJURY OR DEATH. LOCK ALL POWER
SOURCES DRIVE IN "OFF" POSITION.
1. Disconnect all electrical power to Drive.
2. Verify power has been disconnected by using a voltmeter to check for voltage at incoming power terminals
(L1, L2, and L3).
3. Wait for the DC bus capacitors to completely discharge.
4. Remove contents from package. Verify that the above mentioned parts are included:
5. install the RS-232 remote interface. First, remove the screw on the front cover of the drive. Next, remove the
small square cover located above the control terminals to access CN1. Install the RS-232 remote interface by
positioning the interface directly above the CN2 connector. Press down on interface until all three tabs snap
into place.
6. Re-attach the front cover and tighten the screw down.
Remote Digital Operator (NEMA 4/12) Option,
Model DS031 & DS033 for GPD 305/J7
WARNING
Yaskawa Electric America, Inc – www.drives.com
02Y00025-0515 Page 1 of 3
Date: 08/28/01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS031 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YASKAWA DS031

  • Page 1 4. Four screws & nuts 5. Eight rubber washers 6. One RS-232 remote operator interface 7. One cable either 1 meter (DS031) or 3 meter (DS033) in length. Hardware Installation WARNING HAZARDOUS VOLTAGE CAN CAUSE SEVERE INJURY OR DEATH. LOCK ALL POWER SOURCES DRIVE IN “OFF”...
  • Page 2 Remote Digital Operator (NEMA 4/12) Option, Model DS031 & DS033 for GPD 305/J7 Flush Mounting. Mount the Digital Operator as follows. 1. Cut the Remote Operator mounting panel as shown in Fig. 1.1 Figure 1.1 (Dimensions in Inches, not actual size) 2.
  • Page 3 Remote Digital Operator (NEMA 4/12) Option, Model DS031 & DS033 for GPD 305/J7 Surface Mounting. Mount the Digital Operator as follows. 1. Cut the Remote Operator mounting panel as shown in Fig. 2.1 Figure 2.1 (Dimensions in Inches, not actual size) 2.

This manual is also suitable for:

Ds033

Table of Contents