Bradley Terreon Classic WF2500 Series Installation Manual

Bradley Terreon Classic WF2500 Series Installation Manual

Hide thumbs Also See for Terreon Classic WF2500 Series:

Advertisement

Quick Links

WF2605
WF3203
For questions regarding the operation, installation or maintenance of this product, visit bradleycorp.com
or call 800.BRADLEY (800.272.3539).
Product warranties and parts information may also be found under "Products" on our website at bradleycorp.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material.
If any parts are missing, do not begin installation until you obtain the missing parts.
215-1833-10 Rev. B; ECN 18-00-009
© 2018 Bradley
Page 1 of 4
7/19/2018
Installation
WF2500 Series Terreon Classic
WF2600 Series Terrazzo
WF2700 Series Stainless Steel
WF2800 Series Bradstone
WF3200 Series Terreon Deep Bowl
TDB3100 Series Terreon Deep Bowl
Read the instructions in this manual before
beginning installation. Save these instructions
and refer to them for inspection, maintenance
and troubleshooting information.
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
P.O. Box 309
+1 262 251 6000
bradleycorp.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Terreon Classic WF2500 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bradley Terreon Classic WF2500 Series

  • Page 1 If any parts are missing, do not begin installation until you obtain the missing parts. P.O. Box 309 Menomonee Falls, WI 53052 USA 215-1833-10 Rev. B; ECN 18-00-009 800 BRADLEY (800 272 3539) © 2018 Bradley +1 262 251 6000 Page 1 of 4 7/19/2018 bradleycorp.com...
  • Page 2: Cleaning And Maintenance

    Cleaning and Maintenance WF2500, WF2600, WF2700, WF2800, WF3200, TDB3100 Series P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Safety Information Installation Turn OFF electrical supply to the unit before installation.
  • Page 3 Cleaning and Maintenance WF2500, WF2600, WF2700, WF2800, WF3200, TDB3100 Series P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Cleaning and Maintenance for Terreon ® Material Description: Terreon is a densified solid surface material composed of bio based resin and is resistant to chemicals, stains, burns and impact.
  • Page 4: Brand Names

    Cleaning and Maintenance WF2500, WF2600, WF2700, WF2800, WF3200, TDB3100 Series P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Cleaning and Maintenance for Terrazzo Material Description: Terrazzo is a mosaic-looking natural stone and concrete material polished to a high gloss and sealed with clear polyurethane resin for long lasting beauty.
  • Page 5 ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com This document describes installation of washfountain bowl and pedestal only. Terreon Classic and Bradstone washfountains are shipped partially pre-assembled. Some optional equipment and accessories are shown for clarity.
  • Page 6 Semi-Circular Bowl and Pedestal Assembly (Terreon and Bradstone ® ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Semi-Circular Washfountain Dimensions (mm) Adjust to Towel Dispenser Mounting Holes 6"...
  • Page 7 Bradstone ® ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Length of Tie Pipe Required for Vent Through Washfountain Column Type Pipe Length 54" Less Soap Dispenser 21-1/2"...
  • Page 8: Rough-In Specifications

    Semi-Circular Bowl and Pedestal Assembly (Terreon and Bradstone ® ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com (mm) Rough-In Specifications Type A 1" NPT Supplies 2"...
  • Page 9 Semi-Circular Bowl and Pedestal Assembly (Terreon and Bradstone ® ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com (mm) Rough-In Specifications Type O 1" NPT Supplies from Off-line vent with Above Must Reduce to 1/2"...
  • Page 10 Semi-Circular Bowl and Pedestal Assembly (Terreon and Bradstone ® ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com (mm) Rough-In Specifications Type B 1" NPT Supplies from Above Must Reduce to 1/2"...
  • Page 11 Semi-Circular Bowl and Pedestal Assembly (Terreon and Bradstone ® ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com (mm) Rough-In Specifications Type H 1" NPT Supplies...
  • Page 12: Installing The Drain

    ® ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Installing the Drain All piping shown in dotted lines Rough in supply and drain piping as to be supplied by installer.
  • Page 13 ® ® WF2503, WF2504, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Bowl Assembly and Mounting NOTICE! The pedestal must be level when secured to floor for proper drainage.
  • Page 14 Sprayheads WF2500, WF2600, WF2700, WF2800, WF3200, TDB3100 Series P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Non-Sectional Sprayhead Repair kit does not include sprayhead grommet. Order as a separate item.
  • Page 15 Sprayheads WF2500, WF2600, WF2700, WF2800, WF3200, TDB3100 Series P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Sprayhead Troubleshooting Problem Cause Solution Water splashes over Foreign matter has reduced the size of Clean the sprayhead: the rim of the bowl.
  • Page 16 Foot Activation - Non-Sectional Semi-Circular Washfountains WF2503, WF2504, WF2603, WF2604, WF2703, WF2704, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Supplies Required by Installer • 1-1/2" vent pipe on types vented through washfountain column •...
  • Page 17 Foot Activation - Non-Sectional Semi-Circular Washfountains WF2503, WF2504, WF2603, WF2604, WF2703, WF2704, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Some optional equipment shown. Type "O" Drain Supplies from Above Type "A"...
  • Page 18 Foot Activation - Non-Sectional Semi-Circular Washfountains WF2503, WF2504, WF2603, WF2604, WF2703, WF2704, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Installing Supplies – B and H Units WITH Soap Option Slide the tie bar over the 1-1/2"...
  • Page 19 Foot Activation - Non-Sectional Semi-Circular Washfountains WF2503, WF2504, WF2603, WF2604, WF2703, WF2704, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Some optional equipment shown. Type "H" Drain Supplies from Below Type "B"...
  • Page 20: Installing The Valve Assembly

    Foot Activation - Non-Sectional Semi-Circular Washfountains WF2503, WF2504, WF2603, WF2604, WF2703, WF2704, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Installing the Valve Assembly Flush supply lines before making connections.
  • Page 21: Installing The Operating Rod

    Foot Activation - Non-Sectional Semi-Circular Washfountains WF2503, WF2504, WF2603, WF2604, WF2703, WF2704, WF2803, WF2804 P.O. Box 309 • Menomonee Falls, WI 53052-0309 • 1 800 BRADLEY • 262 251 6000 • bradleycorp.com Installing the Operating Rod Insert the operating rod in the operating rod lever (or operating cross if equipped) and then into the foot lever.

Table of Contents