b ) If the use of a guard is recommended for wire
brushing, do not allow any interference of the
wire wheel or brush with the guard. Wire wheel or
brush may expand in diameter due to work load and
centrifugal forces.
Additional Safety Rules for Grinders
Do not use Type 11 (flaring cup) wheels on this tool.
Using inappropriate accessories can result in injury.
Always use side handle. Tighten the handle securely. The
side handle should always be used to maintain control of the
tool at all times.

WARNING: We recommend the use of a residual current
device with a residual current rating of 30mA or less.
Residual Risks
In spite of the application of the relevant safety regulations
and the implementation of safety devices, certain residual risks
cannot be avoided. These are:
Impairment of hearing.
Risk of personal injury due to flying particles.
Risk of burns due to accessories becoming hot
during operation.
Risk of personal injury due to prolonged use.

Electrical Safety

The electric motor has been designed for one voltage only.
Always check that the power supply corresponds to the voltage
on the rating plate.
Your D
WALT tool is double insulated in accordance
e
with EN60745; therefore no earth wire is required.

WARNING: 115 V units have to be operated via a fail-safe
isolating transformer with an earth screen between the
primary and secondary winding.
If the supply cord is damaged, it must be replaced by a
specially prepared cord available through the D
service organisation.
nOTE: This device is intended for the connection to a power
supply system with maximum permissible system impedance
Zmax of 0.28 Ω at the interface point (power service box)
of user's supply. The user has to ensure that this device is
connected only to a power system which fulfills the requirement
above. If necessary, the user can ask the public power supply
company for the system impedance at the interface point.
Mains Plug Replacement
(U.K. & Ireland Only)
If a new mains plug needs to be fitted:
Safely dispose of the old plug.
Connect the brown lead to the live terminal in the plug.
Connect the blue lead to the neutral terminal.

WARNING: No connection is to be made to the
earth terminal.
Follow the fitting instructions supplied with good quality plugs.
Recommended fuse: 13 A.
30
Using an Extension Cable
If an extension cable is required, use an approved 3–core
extension cable suitable for the power input of this tool (see
Technical Data).The minimum conductor size is 1.5 mm
maximum length is 30 m.
When using a cable reel, always unwind the cable completely.

Package Contents

The package contains:
1 Angle grinder
1 Guard
1 Side handle
1 Flange set
1 Two-pin spanner
1 Instruction manual
Check for damage to the tool, parts or accessories which may
have occurred during transport.
Take the time to thoroughly read and understand this manual
prior to operation.
Markings on Tool
The following pictograms are shown on the tool:
Read instruction manual before use.
Wear ear protection.
Wear eye protection.
Visible radiation. Do not stare into light.
Date Code Position (Fig. A)
The date code 
is printed into the housing.
WALT
e
Example:
Description (Fig. A, D)

WARNING: Never modify the power tool or any part of it.
Damage or personal injury could result.
On/off trigger
1
Lock-off button
2
Spindle lock
3
Spindle
4
Guard
5
Guard screw
6
Side handle
7
Lock-on button
8
Two-pin spanner
9
Backing flange
10
Threaded clamp nut
11
 24 