Download Print this page

WimTec SanTec ECOLINE Installation And Operating Instructions Manual page 14

Advertisement

Selection of function programme
GB
14
ATTENTION!
Adjustment of flushing programs only
possible in the first 10 s after initiation
(as soon as battery will be inserted or power
unit will be connected)
Program 1 factory-made pre-adjusted.
For changing the flushing program of an already
adjusted control, the power supply must be
disconnected for at least 60 s, afterwards a new
programming is possible.
Establish reflex with the hand (Hold hand 2 cm in
front of the sensor window)
Red LED flashes:
*
**
***
****
*****
******
******* Seventh = Prog. 7 - for small washbasins
Remove hand at the desired program (LED
1 x . . 2 x . . 3 x . .
flashes x times) - the control confirms the
program by flashing twice quickly.
Afterwards there are further 10 s for changing
the flushing program again. After lapse of this
time, the device flashes 3 times quickly and it
changes into normal function.
Once = Prog. 1 - without continuous
flow resp. continuous flow
Twice = Prog. 2 - Continuous flow
Third = Prog. 3 - Cleaning stop
Fourth = Prog. 4 - Continuous flow and
cleaning stop
Fifth = Prog. 5 - Continuous flow for
thermal disinfection, hygiene flush 3 h
Sixth = Prog. 6 - Continuous flow for
thermal disinfection, hygiene flush 24 h