Technical Specifications

8
Table 1. Model 7610 DSU Technical Specifications (1 of 2)
Item
Housing
Height (including feet)
Height (without feet)
Width
Depth (case)
Depth (case and connectors)
Weight
Power
Normal service voltage
range
Approvals
FCC Part 15
FCC Part 68
Safety Certifications
Industry Canada CS-03
Interface and Connectors
25-pin D-subminiature
connector
34-pin MS34 connector
Physical Environment
Operating Temperature
Storage Temperature
Relative Humidity
Shock and Vibration
Heat Dissipation
Network Interface
Data rates
LADS data rates
Services supported
Terminal Port Data Rates
Management Port Data
Rates
November 1997
Specifications
2.13 inches (54.1 mm)
1.99 inches (50.6 mm)
9.10 inches (231.2 mm)
6.20 inches (157.5 mm)
6.51 inches (165.3 mm)
1.44 pounds (0.65 kg)
Input:
120 Vac +12 Vac, 60 Hz +3 Hz
4.9 watts (max.) at 120 Vac
Class A digital device
Refer to the equipment's label for Registration Number.
Refer to the equipment's label for approvals on product.
Refer to the equipment's label for Certification Number.
EIA-232/ ITU V.24 (ISO 2110) for Terminal and
Management Ports
ITU V.35 (ISO 2593) for DTE Port
32 to 122 F (0 to 50 C)
– 4 to 158 F (–20 to 70 C)
5% — 95% (noncondensing)
Withstands normal shipping and handling
11.6 Btu/hr. (max.) at 120 Vac
56 kbps and 64 kbps clear channel (CC)
56 kbps and 64 kbps
4-wire service
2.4, 4.8, 9.6, 14.4, 19.2, 28.8, and 38.4 kbps
Defaults: 9.6 kbps with 8 bits per character, 1 stop bit,
and no parity
2.4, 4.8, 9.6, 14.4, 19.2, 28.8, and 38.4 kbps
7610-A2-GN10-20