Start-up Checklist

10
Table 3. Model 7610 DSU LADS (Local Area Data Set) Connection Distances
Wire Diameter (AWG)
19 Gauge
(.0359 or
Data Rate
.9122 mm)
(kbps)
56
10.84 mi
(17.45 km)
64
10.69 mi
(17.2 km)
The User's Guide contains details regarding the Asynchronous Terminal Interface
(ATI). When setting up the ATI:
Refer to About the SNMP DSU , Chapter 1, to determine the management
configuration(s) to manage the DSU with one of the user interfaces:
— Locally through the Terminal port or by NMS connection through the
Management port
— Remotely via Telnet session, through the Management port or the
In-Band Management Channel (IMC)
— Out-of-band, using an external modem through the Terminal port or the
Management port
Set-up the Identity and Call Setup administrative screens. Refer to Startup ,
Chapter 3.
Establish security and Login IDs; refer to Security , Chapter 4.
Decide on an IP addressing scheme. Refer to IP Addressing , Chapter 5.
Determine whether you want ASCII alarms and/or SNMP traps generated.
Refer to Messages and Troubleshooting, Chapter 8 .
Change configuration option settings. Refer to Configuration Option Tables ,
Appendix A, and Worksheets , Appendix B.
Provide management connectivity with SNMP and enterprise-specific MIBs.
Refer to Appendix C and Appendix D.
November 1997
22 Gauge
24 Gauge
(.0253 or
(.0201 or
.643 mm)
.511 mm)
6.4 mi
4.50 mi
(10.3 km)
(7.24 km)
6.06 mi
4.47 mi
(9.76 km)
(7.2 km)
26 Gauge
(.0159 or
.404 mm)
3.34 mi
(5.37 km)
3.20 mi
(5.15 km)
7610-A2-GN10-20