Wiring

A multicolor LED CC series lightbar has a 2-wire power cable and a 16-wire control cable. The entire power load of the bar goes through the
power cable. The black ground wire should be connected directly to the battery. The 10 AWG red power wire requires a constant 10 to 16V
power source with a customer supplied in line fuse. To select an appropriately rated ATO (regular) or Maxi Fuse, add the amp ratings, found
in the specifications section, of the modules in your configuration specific lightbar and based on that sum, insert a fuse of the next larger size
(to be no larger than a 30 A fuse). The 16 control cable wires carry only low power (30 mA average) input signals to control the lightbar func-
tions and must be routed to the output of a control switch (or directly to multiple switches).
Before attempting to connect the lightbar wiring harness, refer to the configuration specific wiring key included with the lightbar for the con-
figuration specific functions of each wire. Use an appropriate high-temperature wiring if it passes through the engine compartment. Use cable
ties and grommets to secure and protect all cables and wires.
Function Wire Color
GRN/BLK
WHT/BLK
RED/BLK
RED
Arrowstik Left
ORG
Arrowstik Right
WHT
Drivers Side Cut
BLK/RED
Pattern Select
BLK
Take Down Flash Take Down/Work Light Wig/Wag Flash
ORG/BLK
Take Down lights Take Down/Work Light Steady Burn
BLU/WHT
Alley Light Flash
BLK/WHT
Left Alley Light
RED/WHT
Right Alley Light
GRN/WHT
Front Cut-Off
BLU/BLK
Rear Cut-Off
GRN
Cruise Lights
BLU
Lightbar DIM
Note:
When the Arrowstik Left and Arrowstik Right wires are both connected to +power, the Center-Out Arrowstik function is activated.
The Front Cut and Rear Cut functions must be used with the greatest care to ensure that the use of these functions do not diminish
the effectiveness of the Emergency Warning signal.
When the Pattern Select wire is connected to +power alone, test mode is enabled to exercise all outputs in sequence.
The Dim Function lowers the brightness of the LEDs in the ArrowStik and Emergency Warning Flash modes.
The WHT Drivers Side Cut wire may be changed to Arrowstik Flash. Please see the Arrowstik flash pattern section below for details.
Function
Description
L1
Level 1 Emergency Mode
L2
Level 2 Emergency Mode
L3
Level 3 Emergency Mode
Left Arrowstik
Right Arrowstik
Cut Driver Side Directional and Alley Lights
Pattern Select
Enables Alley Light Wig/Wag Flash
Left Alley Steady Burn
Right Alley Steady Burn
Blacks-Out Front Facing LEDs
Blacks-Out Rear Facing LEDs
End LEDs only
Sets LEDs to DIM mode

Standard Wire Functions

TABLE 1
Notes
Overrides L1, L2 & L3 for rear of lightbar
Overrides L1, L2 & L3 for rear of lightbar
Designed to interface with the driver's door switch
Overrides Take Down Flash
Overrides Alley Light Flash
Overrides Alley Light Flash
Overridden by all other functions except Dim