Download Print this page

Linksys SPA1 Series Installation & Provisioning Manual page 9

Ata

Advertisement

Where it is required for remote programming to be initiated from the Alarm Company
office, it may be necessary to fix the internal IP address of the device and port forward
UDP port 6000 in the client router to the Linksys ATA connected to the alarm panel.
The Alarm Dealer requires a specially provisioned Linksys device at his office for Remote
Programming.
We have found that certain panels perform better with different bandwidth settings. You
can change the Bandwidth setting during provisioning. Here are some recommendations:
DSC – Maximum
Napco – Normal
Alternative method of enabling the web interface for the WAN port
Prior to provisioning launch a web browser on a PC connected to the ETHERNET port of
the Linksys adapter. Enter the adapters default IP address, 192.168.1.1/admin/advanced
into the URL bar and press Enter. Select the Router tab and then the WAN Setup tab. Set
Enable WAN Web Server to "yes" and click on the Submit button. You can now disconnect
your PC from the ETHERNET port and reconnect it into the router.
Make sure your computer's Ethernet adapter is set to obtain an IP address
NOTE:
automatically (DHCP)
.
Setting your Linksys ATA to use a fixed internal IP address
Log into the web interface and go to the System tab. Set DHCP to "no". Enter a Static IP,
NetMask and Gateway plus the Primary and Secondary DNS Server IP addresses. Save
your changes.