6 MAINTENANCE
Use maximum care in handling optical fiber cables. To avoid breakage, do
not reduce the bending radius to 30 mm or less.
Clean the optical module receptacle and optical connectors after
measurement.
Because the SD.LINK module (LQE530) uses a Type SC (or 2SC) optical
connector, the optical power meter must support Type SC (or 2SC)
accordingly. Use a Type SC (or 2SC) connector adapter (included with the
optical power meter or sold separately).

6.5.2 Locating fault portion

Optical receive
level error
(*1) See "6.2 Handling Optical Fiber Cable and Connector."
(*2) See "6.5.1 Optical receiving level measurement."
(*3) See "6.5.3 Optical transmitting level measurement."
Clean the optical connector
at the transmitting/receiving
end
(*1)

Figure 6-3 Locating Faults

NOTICE
Replace the
adjoining SD.LINK
Measure the optical
receive level again
OK
(*2)
END
6-10
NG
Measure the optical transmit
level of the adjoining SD.LINK
OK (*3)
<Transmission line fault>
The cable may be at fault.
Contact the installation personnel.
NG