SPECIFICATIONS

Models
Operating Specifications
Temperature: 0 to 150 degrees F
Pressures: up to 200 PSI
Humidity: up to 100%
Additional Features
Programmable Start Up Delay (0 to 300 seconds)
Programmable Interrupt Period (2 to 60 minutes)
System Status Indicator Light
One Button System Calibration
FLOW RANGE
Operating Range (GPM)
Flow Sensor
Diameter
Minimum*
Suggested Maximum**
1"
6
1½"
13
2"
20
3"
40
4"
60
*
Minimum recommended flow for the highest flow zone for your system
** Good design practice dictates the maximum flow not to exceed 5ft/sec.
Suggested maximum flow is based upon Class 200 IPS plastic pipe

FLOW SENSOR PRODUCT COMPARISON

FEATURES
Flow monitoring for less than $200 (1½" vavle)
Programmable startup delay
User adjustable set point
Programmable automatic controller reset
Fast, easy hookup on any Hunter controller
Easily adaptable to other manufacterrs controllers
Installation type
Pressure: up to 150 PSI
Rain Bird
is a registered trademark of Rain Bird Sprinkler Manufacturing Corporation
®
Data Industrial
is a registered trademark of Data Industrial Corporation
®
Maximum (for sensor)
17
50
35
100
55
200
120
300
200
400
Hunter
Flow-Clik™
®
20-300 sec.
2-60 min.
Male Threaded Tee
Flow-Clik
Electrical Specifications
Current Draw: (@ 24VAC) .025 amps
Switching Current: 2.0 amps
Maximum Distance between Interface Box and
Sensor = 1,000 ft.
Dimensions
Flow-Clik Interface Box (4.5"H x 5.5"W x 1.5"D)
Flow-Clik Sensor Body (FCT Series)
FCT 100 (4.8"H x 2.3"W x 4.5"L)
FCT 150 (5.4"H x 2.3"W x 4.6"L)
FCT 158 (5.4"H x 2.3"W x 5.1"L)
FCT 200 (5.9"H x 2.7"W x 4.7"L)
FCT 208 (6.0"H x 2.9"W x 5.4"L)
FCT 300 (7.0"H x 4.0"W x 6.2"L)
FCT 308 (7.0"H x 4.2"W x 6.4"L)
FCT 400 (6.5"H x 5"W x 6.5"L)
Data Industrial 200 Series
up to 100 sec.
manual reset
Needs separate relay control
(LARC) and relays
Saddle tee
S P E C I F I C A T I O N G U I D E
FLOW-CLIK - 150
EXAMPLE:
MODEL
FLOW-CLIK = Standard Ver-
sion for all 24VAC Controllers
(includes sensor and
interface panel)
FLOW-CLIK IMMS = Version
for use with IMMS™
Central Control (includes
sensor only - interface panel
not required for IMMS™)
NOTE = Order Flow-Clik Sensor Bodies Separately (FCT series)
Sensor
Rain Bird FS-P Series
Separate transmitter,
power supply and software
Glue-in Tee
FEATURES
100 = 1" Schedule 40 Sensor Body
150 = 1½" Schedule 40 Sensor Body
158 = 1½" Schedule 80 Sensor Body
200 = 2" Schedule 40 Sensor Body
208 = 2" Schedule 80 Sensor Body
300 = 3" Schedule 40 Sensor Body
308 = 3" Schedule 80 Sensor Body
400 = 4" Schedule 40 Sensor Body
35