REPLACEMENT PARTS

Item
Description
1
Cap and Spindle Assembly
2
Vent Ring
3
Switch Housing
4
Switch
5
Bracket
6
Inside Housing Bracket Screw
7
Outside Housing Bracket Screw
8
Housing Bracket Locknut Set (2)
Note:
Part numbers 1 through 4 are common to Mini-Clik
and Mini-Clik-C.
1/8
1/4
1/2
3/4
1
1
2
3
4
5
Mini-Clik
WIND-CLIK
SENSOR
Control Irrigation System Operation
Catalog No.
During High Winds
440200
The Wind-Clik Wind Sensor acts as a switch to break
440100
the circuit to the solenoid valves of the irrigation
440000
system during windy conditions. This allows the timer
206431
to advance as scheduled, but stops the valves from
activating (not allowing water to flow). Once the wind
439700
conditions drop below the reset point, the switch closes
194986
again to allow for normal operation. The Wind-Clik
201532
can be used in conjunction with other sensors to en-
206498
hance the overall automation of any irrigation system.
Mount the unit in an area that receives prevailing winds
without hindrance.
PRODUCT FEATURES
AND BENEFITS
Installs Simply and Easily...
6
No adjustments necessary
The Wind-Clik is designed to install
directly to a "normally closed" or
7
"normally open" controllerʼs sensor
terminals or in the common wire
circuit between the zone valves and
8
the controller. If multiple commons
are used in the system, the Wind-Clik must be tied in to
the end of all the common wires, then connected to the
controller. If the Mini-Clik
installed or is to be part of the system, the wind sensor is
to be wired in series with the other sensors so either or
both devices can control the circuit.
Designed for "Normally Closed" or "Normally
Open" Operation...
Versatile to meet the needs of all controllers
The type of controller used on the job will not be a
concern for the installer because the Wind-Clik is
designed to work with either "normally closed" or
"normally open" sensor circuits. The unit comes from
Hunter with three colored wires attached ready for
installation. Depending on what the controller sensor
circuitry is, the installer will hook up the green and red
wires for "normally closed" and hook up the green and
blue wires for "normally open" systems.
/ Wind-Clik
®
WIND
®
or Freeze-Clik
®
Sensor
®
is already
®