Sweep Mode; Sweep Time - ADVANTEST R3131 Series Operation Manual

Spectrum analyzer
Hide thumbs Also See for R3131 Series:
Table of Contents

Advertisement

R3131 Spectrum Analyzer Operation Manual
GPIB Remote Programming
Function

Sweep mode

Normal
Single
Reset & Start
(Take sweep)
Reset & Start
Function

Sweep time

Sweep auto
Gate Sig External O N
Function
RBW
RBW auto
VBW
VBW auto
Couple all auto
4-16
Table 4-4 Sweep Mode
Listener Code
CONTS
SN
SI
SNGLS
TS
SR
Table 4-5 Sweep Time
Listener Code
SW*
SW?
ST*
ST?
AS
AS?
GEXON?
GEX1
OFF
GEXO
Table 4-6 Bandwidth
Listener Code
RB*
BA
VB*
VA
AL
Talker Request
Code
SWM?
O:Normal & Full
1:Normal & Window
20:Single & Full
21:Single & Window
Talker Request
Output Format
Code
Sweep Time
Sweep Time
O:Manual/ 1:Auto
O:OFF
1:0N
Talker Request
Code
RBW frequency
RB?
O:Manual/ 1:Auto
BA?
VB?
VBW frequency
O:Manual/ 1:Auto
VA?
O:Manual/ 1:Auto
AL?
Output Format
Output Format

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R3131 Series and is the answer not in the manual?

This manual is also suitable for:

R3131a