Alto-Shaam Halo Heat ITM-48 Installation Operation & Maintenance

Alto-Shaam Halo Heat ITM-48 Installation Operation & Maintenance

Island takeout merchandiser
Hide thumbs Also See for Halo Heat ITM-48:

Advertisement

Quick Links

I s l a n d T a k e o u t
®
M e r c h a n d i s e r
Models:
ITM-48
ITM-72
• I N STALLATION
• OPERATION
• MAI NTENANCE
W 1 6 4 N 9 2 2 1 W a t e r S t r e e t • P. O . B o x 4 5 0 • M e n o m o n e e F a l l s , W i s c o n s i n 5 3 0 5 2 - 0 4 5 0
U S A
: 262.251.3800 • 800.558.8744
/
: 262.251.7067 • 800.329.8744
.
.
.
PHONE
USA
CANADA
FAX
U
S
A
ONLY
: www.alto-shaam.com
WEBSITE
# 8 8 0 • 11 / 0 6
.
.
.
P R I N T E D I N U
S
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Halo Heat ITM-48 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alto-Shaam Halo Heat ITM-48

  • Page 1 W 1 6 4 N 9 2 2 1 W a t e r S t r e e t • P. O . B o x 4 5 0 • M e n o m o n e e F a l l s , W i s c o n s i n 5 3 0 5 2 - 0 4 5 0 U S A : 262.251.3800 • 800.558.8744 : 262.251.7067 • 800.329.8744 PHONE CANADA ONLY : www.alto-shaam.com WEBSITE # 8 8 0 • 11 / 0 6 P R I N T E D I N U...
  • Page 2 ® D E L I V E RY U N PA C K I N G 1. Carefully remove the This Alto-Shaam appliance has been appliance from the thoroughly tested and inspected to insure only carton or crate. the highest quality unit is provided. Upon...
  • Page 3 SAFETY PROCEDURES A N D P R E C A U T I O N S Knowledge of proper procedures is essential to the 1. This appliance is intended to cook, hold or safe operation of electrically and/or gas energized process foods for the purpose of human equipment.
  • Page 4: Site Installation

    This Alto-Shaam appliance is designed for the purpose of maintaining hot food at a temperature for safe consumption. The unit must be...
  • Page 5 I N S T A L L A T I O N SITE INSTALLATION I T M - 4 8 O P T I O N S & A C C E S S O R I E S Exterior Base Panels Custom color P146 Stainless steel side, 2...
  • Page 6: Electrical Connection

    I N S T A L L A T I O N ELECTRICAL CONNECTION 1. An identification tag is permanently mounted 230V: To prevent an electrical shock hazard on the unit. between the appliance and other appliances or metal parts in close vicinity, an equalization- bonding stud is provided.
  • Page 7: Operation

    O P E R A T I O N U S E R S A F E T Y I N F O R M AT I O N This appliance is intended for use in commercial establishments by qualified personnel who are familiar with the purpose, limitations, and associated hazards of this appliance.
  • Page 8 O P E R A T I O N BEFORE INITIAL USE: Perimeter panel Before operating the unit, clean both the interior and exterior of the unit with a damp cloth and Indicator light mild soap solution. Rinse well. On/Off switch Breaker switch Turn the breaker switch "ON".
  • Page 9: General Holding Guidelines

    O P E R A T I O N GENERAL HOLDING GUIDELINES Chefs, cooks and other specialized food service personnel employ varied methods of H O L D I N G T E M P E R A T U R E R A N G E cooking.
  • Page 10: C L E A N I N G A N D P R E V E N T I V E M A I N T E N A N C E

    C A R E a n d C L E A N I N G C L E A N I N G A N D P R E V E N T I V E M A I N T E N A N C E PROTECTING STAINLESS STEEL SURFACES CLEANING AGENTS It is important to guard against...
  • Page 11 C A R E a n d C L E A N I N G The cleanliness and 4. Wipe control panel, any vents, handles, and appearance of this gaskets thoroughly since these areas harbor equipment will contribute food debris. considerably to operating efficiency and savory, 5.
  • Page 12 S A N I TAT I O N Food flavor and aroma are usually so closely The most accurate method of measuring safe related that it is difficult, if not impossible, to temperatures of both hot and cold foods is by separate them.
  • Page 13 S E R V I C E Description ITM-48 Qty. ITM-72 Qty. Bulb, 60W, 130V, coated LP-33598 LP-33598 Bulb Receptacle RP-3955 RP-3955 Cord Set, electric, CD-33672 CD-33673 NOT SHOWN Block, 4 terminal, BK-3023 BK-3023 NOT SHOWN Circuit Breaker, Switch, 15 Amp SW-33342 SW-33342 Circuit Breaker, Switch, 30 Amp...
  • Page 14 S E R V I C E 2 2 6 6 Gasket 2 2 5 5 Glass sneezeguard GL-22593 GS-22547 ITM-48 3 3 7 7 Pan Insert 5000182 3 3 3 3 Customer side, Trim 5000096 2 2 9 9 2 2 9 9 1 1 6 6 3 3 1 1...
  • Page 15 S E R V I C E Cable wrap 1 1 3 3 Inside the control panel 1 1 1 1 1 1 0 0 1 1 2 2 1 1 2 2 Circuit Breaker, 15 Amp ON/OFF Light Switch SW-33342 Circuit Breaker, 30 Amp SW-3715...
  • Page 16 S E R V I C E Heated well can be lifted for servicing cable heating element. Assembled Well #55654 Assembled Well #55655 ITM - 48 ITM-72 Cable Heating Service Kit ..... No. 4880 Cable Heating Service Kit.
  • Page 17 S E R V I C E 1 1 7 7 Glass Clamp CM-26985 or CM-26986 1 1 8 8 Bumper to protect glass DR-2533 Bulb LP-33598 Bulb Receptacle RP-3955 1 1 7 7 1 1 7 7 2 2 0 0 Guard, thermostat capillary GD-2536 1 1 8 8...
  • Page 18 # 8 8 0 • I N S TA L L AT I O N / O P E R AT I O N / S E RV I C E M A N U A L • 17.
  • Page 19 # 8 8 0 • I N S TA L L AT I O N / O P E R AT I O N / S E RV I C E M A N U A L • 18.
  • Page 20: Limited Warranty

    ALTO-SHAAM, INC. RECORD THE MODEL AND SERIAL NUMBER OF THE APPLIANCE FOR EASY REFERENCE. ALWAYS REFER TO BOTH MODEL AND SERIAL NUMBER IN ANY CONTACT WITH ALTO-SHAAM REGARDING THIS APPLIANCE. Model: Date Installed:...

This manual is also suitable for:

Halo heat itm-72

Table of Contents