Cn1610 Port Assignments - IBM System Storage N Series Setup And Configuration Manual

Clustered data ontap switch
Hide thumbs Also See for System Storage N Series:
Table of Contents

Advertisement

1
and Port 16 of each switch. In any switch configuration, a minimum of two links
aggregation with spanning tree must be created and set. Therefore, this may not
necessarily be Port 15 and 16 on your switch.

CN1610 port assignments

You can use the CN1610 port assignment table as a guide to configure your cluster.
CN1610 port assignment table
Ports 1-12 are configured as cluster ports. This does not indicate the number of
supported nodes for Cluster-Mode. To use any unconnected ports for other
administrative purposes, you must manually reconfigure them. For specific port
settings, see the latest reference configuration file (RCF) available from
http://www.ibm.com/storage/support/nseries. The sample port definition on
each pair of switches is as follows:
10
IBM System Storage N series: Clustered Data ONTAP Switch Setup and Configuration Guide
Management switch A
Switch port
Node/port usage
10
Node management
connectivity
11
Node management
connectivity
12
Node management
connectivity
13
Cluster switch A
service port
14
Customer
management network
15
Switch B port 15
1
(link aggregation)
16
Switch B port 16
1
(link aggregation)
In this 16 port switch example, you need to create a link aggregation for Port 15
CN1610 cluster switch A
Switch port
Node/port usage
Serviceport/wrench
Admin net or
port (out-of-band
management switch
management port)
1
Node 1 cluster port 1
2
Node 2 cluster port 1
3
Node 3 cluster port 1
4
Node 4 cluster port 1
5
Node 5 cluster port 1
6
Node 6 cluster port 1
7
Node 7 cluster port 1
8
Node 8 cluster port 1
9
Node 9 cluster port 1
Management switch B
Switch port
Node/port usage
10
Node management
connectivity
11
Node management
connectivity
12
Node management
connectivity
13
Cluster switch B
service port
14
Customer
management network
15
Switch A port 15
1
(link aggregation)
16
Switch A port 16
1
(link aggregation)
CN1610 cluster switch B
Switch port
Node/port usage
Serviceport/wrench
Admin net or
port (out-of-band
management switch
management port)
1
Node 1 cluster port 2
2
Node 2 cluster port 2
3
Node 3 cluster port 2
4
Node 4 cluster port 2
5
Node 5 cluster port 2
6
Node 6 cluster port 2
7
Node 7 cluster port 2
8
Node 8 cluster port 2
9
Node 9 cluster port 2