System Filling - Immergas MAGIS PRO 4 V2 Instructions And Recommendations

Hide thumbs Also See for MAGIS PRO 4 V2:
Table of Contents

Advertisement

Key (Fig. 11, 12, 13, 14, 15, 16)
1
- Central Heating Set
2
- Cooling Set
Rxx
- "Temperature control" menu parameter
TE
- External temperature
TM
- Flow temperature
U01
- Zone 2 flow temperature in "User" menu central heating
mode
U02
- Zone 2 flow temperature in "User" menu cooling mode
U003
- Offset value compared to the curve set by the external probe
on central heating zone 1.
U004
- Offset value compared to the curve set by the external probe
on central heating zone 2.
U005
- Offset value compared to the curve set by the external probe
on cooling zone 1.
U006
- Offset value compared to the curve set by the external probe
on cooling zone 2.
U014
- Zone 3 flow temperature in "User" menu central heating
mode (available from revision 2.0 of the P.C.B. firmware).
U015
- Zone 3 flow temperature in "User" menu central heating
mode (available from revision 2.0 of the P.C.B. firmware).
U016
- Offset value respect to curve set by external probe on heating
zone 3 (available from revision 2.0 of the P.C.B. firmware).
U017
- Offset value respect to curve set by external probe on cooling
zone 3 (available from revision 2.0 of the P.C.B. firmware).
Zx
- Heating system zone
20

1.17 SYSTEM FILLING

Once the hydronic module is connected, fill the system using the
filling cock (Fig. 21).
The hydronic module has one incorporated automatic vent valve
located on the circulator pump and another on the central heating
manifold.
Make sure that the hoods are loosened.
The filling cock must be closed when the hydronic module pressu-
re gauge indicates approximately 1.2 bar.
During these operations, enable the "Venting" fun-
ctions by setting the "M01" parameter to ON, which lasts
about 18 hours (Parag. 3.9).
System minimum water content.
Minimum water content favours the proper execution of defro-
sting cycles and operation in cooling mode.
To this end, the minimum amount of water to guarantee is 30 li-
tres for any type of system and in any operating mode.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magis pro 6 v2Magis pro 9 v2

Table of Contents