SYSTEM TROUBLESHOOT

Problem
Cause
1) The control fails
A) Disconnected meter cable
to Regenerate
B) Transformer damaged
automatically
C) Electronic controller or sensor
damaged
2) Regeneration at
A) Timer improperly set, due to
wrong time
power failure
3) loss of capacity
A) Increase draw water hardness
B) Brine concentration or quantity
C) Rinse fouling
D) Poor distribution, channeling
(Uneven bed service)
E) Internal control leak
F) Aging of rinse
G) Loss of rinse
4) Poor water
A) Check items listed in Problem # 3 A) Check items listed in Correction # 3
quality
B) Bypass is open
C) Channeling
5) Excessive salt use A) High salt setting
B) Excessive water in brine tank
6) Loss of water
A) Fouling of inlet pipe
pressure
B) Fouled resin
C) Improper backwash
7) Excessive water
A) Plugged drain line
in brine tank
B) Brine valve plugged or damaged
C) Injector plugged
D) Low inlet water pressure
8) Softener fails to
A) Plugged drain line
brine draw
B) Plugged injector
C) No water in the brine tank
D) Low water pressure
E) Brine line injects air during brine
draw
F) Internal control leak
9) Control cycles
A) Faulty timer
continuously
10) Continuous flow
A) Foreign material in the control
to drain
B) Internal control leak
C) Piston jammed in brine or back
wash position
SEE THE AQUATROL MANUAL FOR ADVANCE INSTALLATION PROCEDURES
Correction
A) Reconnect the meter cable
B) Replace the transformer
C) Replace or repair
A) Reset timer
A) reset unit to the new capacity
B) Keep brine tank full of salt at all times. Clean it yearly. Salt may be
bridged. If using a salt grid Plate insure refill water is over it
C) Consolidate the rinse tank, clean the rinse and prevent future
fouling
D) Check distributors and backwash flow
E) Replace the spacer, seal or piston
F) Check for resin oxidation caused by Chlorine. Mushy resin
G) Check for correct bed depth. Broken distributors. Air or gas in
bed: Well gas Eliminator loose brine line
B) Close the bypass
C) Check for too slow or high service flow
A) adjust salt setting
B) refer to problem # 7 tank
A) Clean or replace the pipeline
B) Clean the resin. Pretreat to prevent
C) Too many resin fines. Reset the flow rate and time of backwash
A) Check drain line and clean flow control
B) Clean or replace the brine valve
C) Clean injector, replace injector screen
D) Increase water pressure to allow Injector to perform properly
A) Clean drain line and flow control
B) Clean or replace the injector and screen
C) Check for restriction in B.L.FC. Ensure Safety float is not stuck
D) Increase water pressure
E) Check brine line for air leaks
F) Check seal, spacer and piston for scratches and dents
A) Replace timer
A) Call dealer. Clean valve, rebuild unit
B) Same as above
C) Same as above