FEATURE & DISPLAYS CONT.
3. Memory During Power Failure
All program settings are stored in permanent memory. Current valve position, cycle step elapsed, time of day are stored during the power failure. Reset the
current time is necessity when power up.
If the valve stopped at a regeneration stage when power failure, the valve will return to prior position when power up. It takes 4 to 5 minutes to reset to the
position.
The display shows as:
The system will show the status when
power failure after find the position.

4. Restore Factory Settings

1) Pull out the power
2) Press the
button and plug in the power simultaneously
3) Release the
button
The system is now restored

5. Manual Queued Regeneration

Queued Regeneration
When the valve is in service position press the
Queued Regeneration means the system will initiate a regeneration at the time set. If missed, it will initiate on the
next day.
The display shows the Queued
Regeneration in TIMER Mode
11:30
Flashing
02:18
The display shows the Queued Regeneration in Meter Delay Mode. The system will initiate a regeneration - either
the treated water remaining counts down to zero or the remaining time counts down to zero, whichever is first.
11:30
Flashing
60
button to activate the queued regeneration.
--- -
M3
11:30
R ESET
Regeneration in Meter Delay Mode
Flashing
Alternating
Display
Flashing
- 24 -
11:30
R ESET
The display shows the Queued
11:30
0 2:18
----
11:30
0 2:18
----