INSPECTION & PREPARATION IMPORTANT! Before installing - Please read the entire manual and become familiar with instructions and parts needed before proceeding with the installation. System Inspection Please take the system and all the components out of the box. Inspect the system and all the connection fittings carefully, make sure nothing is damaged during shipping.
Page 4
INSPECTION & PREPARATION CONT. II. System Operation Parameter and Installation checklist IMPORTANT! The following condition for feed water supply must be met or warranty will be void and manufacturer assumes no responsibility for damage to system or property. 1. Water Temperature Parameters System must not be installed at an area where it is exposed to direct sunlight and must be protected against freezing and extreme heat.
Page 5
INSPECTION & PREPARATION CONT. III. Installation Safety Guide • Handle with care when moving the water softening system. Do not turn upside down, drop, drag, or set on areas with sharp protrusions. • The system works on standard 110v power plug only. Do not use any other transformer except the ones that is included with the system •...
VALVE SETUP IMPORTANT! Locate and test the main water supply valve to the home before installing the system. If the main water supply valve fails to shut off the water completely during the test, we recommend contacting a licensed plumber to fix the valve before begin installing the system. WARNING! If the system is installed on a metal (Conductive) plumbing system, i.e..
Page 8
VALVE SETUP CONT. 4. Attached the other end of the bypass valve onto the control head and secure it with the metal plate. Make sure the o-rings are lubricated before installing. Softener Preparation 1. Remove the resin tank from carton 2.
SYSTEM INSTALLATION 3. Lubricate the riser tube located on the opening of the tank. 4. Install the upper basket on the bottom of the valve by lining up the tabs, pressing in, then turning the basket counterclockwise to lock it in place.
Page 10
SYSTEM INSTALLATION CONT. IMPORTANT! On copper plumbing systems be sure to install a grounding wire between the inlet and outlet piping to maintain grounding. WARNING! Any solder joints being soldered near the valve must be done before connecting any piping to the valve. Always leave at least 6”...
Page 11
SYSTEM INSTALLATION CONT. 6. Push the brine line into the brine line connector 7. Connect the brine line to the brine tank by pushing 1/2” and secure it by pushing in the locking clips. the brine line through the hole in the side of the Pull on the brine line to ensure it is secure.
VALVE PROGRAMING System Startup 1. Flow Meter Indicator 11:30 2. Time of Day 10 00 3. Status 4. Volume Remaining 5. Regeneration Mode Timer Meter Immediate Meter Delay Setting Button 1. Enter into setting menu 2. Confirm the current setting, and enter into the next step 3.
Page 13
VALVE PROGRAMING CONT. 4. When the backwash cycle is complete, the valve will advance to the brine draw (BD) position. Once the valve reaches the BD cycle, push and release the “Cycle” button. The display will show “GOTO RR” (Rapid Rinse). Once the valve reaches the rinse cycle, allow the water to run for the entire rinse cycle 5.
Page 14
VALVE PROGRAMING CONT. 2. Setting the Regeneration Mode 11:30 Default setting is "Timer" SET- 2TYPE NOTE: See page 22 for feature and display in regards to each of the three regeneration mode. Choose the Flashing mode that best fit your need. Set To Meter Delayed / Timer Meter (TM) 11:30 Timer...
Page 15
VALVE PROGRAMING CONT. 3. Setting the Unit Capacity (Not shown if Timer Mode was selected in 2nd Step) 11:30 Default setting is 1000 gal SET -3 C-U Flashing Set Unit Measurement To Gallons (GAL) 11:30 Gallons (Recommended) 0 100 0 G AL Press Up or Down buttons to Change Unit...
Page 16
VALVE PROGRAMING CONT. NOTE: Complete the gallons needed using the worksheet on page 21. 01000 G AL Enter the number of gallons that was determined in the Total Gallons Calculation worksheet in page 21. Flashing This worksheet must be completed to determine the proper gallons.
Page 17
CONGRATULATION! Your system is ready to use. Please document the system installation time and maintain the system at its recommended interval. ADVANCE SETTINGS: Settings 4 to 8 have been pre-set from the factory and are only meant for special application that requires customized settings.
ADVANCE SETTINGS 4. Regeneration Time and Hours Override (Change only if needed) 11:30 SE T-4 T -H Flashing Timer Mode Meter Imm & Meter Delay Modes (Recommended) Default: 2:00 a.m. – 072 hours Default: 2:00 a.m. – OFF Hours Override range: Hours Override range: 3, 4, 6, 8, 12 hours, then every 24 hours (24, 48, 76,…) Every 24 hours (24, 48, 76…...
Page 19
ADVANCE SETTINGS CONT. 5. Setting the Back Wash Time 11:30 SE T-5 -BW- Flashing Set the Time 11:30 Default setting is 015 -B W- Flashing Press Up or Down buttons to change Back Wash time (Minutes) Range: 0 - 999 11:30 -B W- Press the Settings Button to accept...
Page 20
ADVANCE SETTINGS CONT. 6. Setting the Brine Time 11:30 SET-6 -BD- Flashing Set the Time 11:30 -BD- Default setting is 060 Flashing Press Up or Down buttons to change Brine time (Minutes) 11:30 Range: 0 - 999 -BD- Press the Settings Button to accept and continue to next digit Flashing...
Page 21
ADVANCE SETTINGS CONT. 7. Setting the Rapid Rinse Time 11:30 S ET-7 -RR- Flashing Set the Time 11:30 -R R- Default setting is 010 Flashing Press Up or Down buttons to change the Rapid Rinse time 11:30 (Minutes) Range: 0 - 999 -R R- Press the Settings Button to accept and continue to next digit...
Page 22
-B F- You are now done setting up your water softening system. Flashing NOTE: Use the table below to determine the proper BF setting for your unit. Parameter PRO-S-80E Grain Capacity 80,000 Brine Fill Settings in Minutes - 21 -...
Total Gallons = System Capacity in Grains (see chart below) / Hardness in (GPG) Grains Per Gallon (determined by water test) - Number of People X 75 Gallons Parameter PRO-S-80E Grain Capacity Setting 80,000 Brine Fill Settings in Minutes...
FEATURE & DISPLAYS 1. Display in Service 11:30 Timed Regeneration Mode The display will show the current time, remaining time to the next set regeneration, and the days override. 02:18 01-D Reg. remaining time Reg. override days 11:30 Meter Immediate Regeneration Mode The display will show the current time and the remaining treated water to the next regeneration.
FEATURE & DISPLAYS CONT. 3. Memory During Power Failure All program settings are stored in permanent memory. Current valve position, cycle step elapsed, time of day are stored during the power failure. Reset the current time is necessity when power up. If the valve stopped at a regeneration stage when power failure, the valve will return to prior position when power up.
FEATURE & DISPLAYS CONT. 5. Manual Immediate Regeneration Immediate Regeneration When the valve is in service position, press and hold the button for 5 seconds, an immediate regeneration will be initiated. Examples: "BW" Flashing (ready to "Backwash") 11:30 GO TO When the time counts down to zero or press the button 11:30...
SYSTEM TROUBLESHOOT Problem Cause Correction 1) The control fails A) Disconnected meter cable A) Reconnect the meter cable to Regenerate B) Transformer damaged B) Replace the transformer automatically C) Electronic controller or sensor C) Replace or repair damaged 2) Regeneration at A) Timer improperly set, due to A) Reset timer wrong time...
LIMITED PRODUCT WARRANTY PRO+AQUA warrants that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble free service. Five Year Valve, Electronics and Resin Guarantee PRO+AQUA will replace any part on the valve or electronics which fails or the softening resin within (5) five years from date of manufacture, as indicated by the serial number, provided the failure is due to a defect in material or workmanship.