Valve Programing - Pro-Aqua PRO-S-80E Owner's Manual

Table of Contents

Advertisement

VALVE PROGRAMING

System Startup
5
1
2
3
4
1. Plug the power transformer into an approved power source. Connect the power cord to the valve.
2. When power is supplied to the control, the screen will display the time of day, gallons remaining and the mode.
Press and hold the "Cycle" button. The valve will display "GOTO BW" and will continue to move until it reaches
the backwash cycle.
3. Once the valve is in the backwash (BW) cycle the display will show a time value (10), open the inlet on the
bypass valve slowly to allow water to enter the unit. Air from the tank will begin to push out of the control valve
drain. Allow all air to escape from the unit before turning the bypass fully open. If there is a large "knocking"
sound, the water is being fed too quickly and should be slowed. Once there is a steady stream of water coming
from the system drain with no air coming out, allow water to run to drain for 3-4 minutes or until all media/ resin
fines are washed out of the softener which is indicated by clear water in the drain hose.
11:30
10 00
Setting Button
1. Enter into setting menu
2. Confirm the current setting, and enter into the next step
3. When used simultaneously with up button, it will enter into master programming
Up / Down Buttons
1. Adjust current settings
2. Go one step forward or backward
Cycle Button
1. Save the setting and return to service
2. Enter into queued regeneration mode
3. A long press for 5 - 6 seconds will initiate a immediate regenerate
4. Terminate the current regeneration step and goes to the next step
GAl
- 11 -
1. Flow Meter Indicator
5
2. Time of Day
3. Status
4. Volume Remaining
5. Regeneration Mode
Timer
Meter Immediate
Meter Delay

Hide quick links:

Advertisement

Table of Contents
loading