REQ5..X, REQ6..X
Door station VIDEO 2-wire
1 1
Safety instructions
Electrical equipment may only be installed and
assembled by a qualifi ed electrician in accor-
dance with the relevant installation standards,
z
guidelines, regulations, directives, safety and
accident prevention regulations of the country.
When installing and laying cables, always com-
ply with the applicable regulations and stan-
dards for SELV electrical circuits.
These instructions are an integral component
of the product and must be retained by the end
user.
Design and layout of the device
(1)
(2)
(3)
(4)
(5)
(6)
Figure 1: Front
(1) Front plate stainless steel
(2) Microphone
(3) Camera
(4) Locating screw for camera
(Allen key supplied)
(5) Twilight sensor for call button/loudspeaker
(6) Button panel with call push-buttons
(7) Cover strip for dismantling protection
(8)
(9)
(10)
(11)
(12)
Figure 2: Back
z
(8) Adjustment button Upwards
(9) 7-segment display
(10) Selection button
(11) Adjustment button downwards
(12) Module connecting cable
(13) Connection terminal block
Function
The door station video works in the 2-wire bus
system and enables communication via sound and
image.
Correct use
- for surface- or fl ush-mounted installation in spe-
cial housings (see Accessories)
- Not compatible with intercom systems of other
manufacturers
- suitable for use exterior applications
Product characteristics
- completely pre-assembled
- protected against vandalism
- with brushed 2 mm stainless steel front plate
- Name plate can be changed from the front wit-
hout any special tools
- One-man commissioning
- Call push-button with acknowledge tone (can
be switched off) and tactile feedback
- Call button, light release or door release can be
adjusted even without any function
- durable, homogeneous, white LED call push-
button backlighting
- Twilight controlled call push-button backlighting
with adjustable switch-on brightness level
- Opening of door station only with enclosed ope-
(7)
ning tool
- break-proof fl ush-mounted call buttons
- Colour camera
- invisible, glare-free IR LED night lighting
- temperature controlled camera heating for clear
view
- scratch-proof camera cover
- Loudspeaker and microphone protected against
sabotage
- Volume and microphone sensitivity settable
- Door release contact on 1 ... 10 s adjustable
- Door release without previous call adjustable in
single door systems
- Safety rope as installation aid
Operation
Establish call (ringing)
 Press the call push-button assigned to the
desired subscriber.
If confi gured, the call push-button activation is
confi rmed by an acknowledge tone. Addressed
indoor stations are called.
Switch-on lights
A call push-button is confi gured and labelled for
lighting control (light insert supplied).
 Press the call push-button for lighting.
If confi gured, the call push-button activation is
confi rmed by an acknowledge tone. The light
(13)
contact of a line power supply is closed for the
set time.
Label call push-button
 Keep call push-button pressed on one side.
On the opposite side, the lever opening (14) is
accessible for a screwdriver.
 Position the screwdriver in the lever opening
(14) and release the interlock (Figure 3).
 Remove cover with name plate insert.

Advertisement

loading

Summary of Contents for hager REQ5 X Series

  • Page 1 Safety instructions (8) Adjustment button Upwards (9) 7-segment display Electrical equipment may only be installed and (10) Selection button assembled by a qualifi ed electrician in accor- (11) Adjustment button downwards dance with the relevant installation standards, (12) Module connecting cable guidelines, regulations, directives, safety and (13) Connection terminal block accident prevention regulations of the country.
  • Page 2: Cleaning And Care

    Information for electricians  Attach the loops of the safety rope (17) to the upper left suspension of the door station and to Installation and electrical connection the upper fastening element (16) in the housing. Place the door station for installation onto the DANGER! ç...
  • Page 3 = Cancel dication goes out = Reset factory setting 1) Door release functions without door call only possible single door systems Figure 10: Overview of system settings Elcom Kommunikation GmbH - Gottfried-Leibniz-Str.1 - D-74172 Neckarsulm - www.hager.com - 08/2015 - 6LE000719A...
  • Page 4 Calling up and changing of system settings  Confi rm set address/function with Inserting door station On the back of the video insert, there are 3 The device applies the setting and returns to The system settings are complete. operating buttons and a 2-digit 7-segment display the previous menu entry.
  • Page 5 Align camera Dismantle call push-button module cover Open door station The camera can be aligned in order to adapt the During cleaning or replacement, the call push-but-  Position the opening tool (16) at the bottom in camera picture to the local circumstances (Figure ton module cover can be dismantled from the front.
  • Page 6 3 und 2 modules or with 2 x 3 modules 225.5 x 422 x 2 mm Elcom Kommunikation GmbH - Gottfried-Leibniz-Str.1 - D-74172 Neckarsulm - www.hager.com - Elcom Kommunikation GmbH - Gottfried-Leibniz-Str.1 - D-74172 Neckarsulm - www.hager.com - 08/2015 - 6LE000719A...

This manual is also suitable for: