Download Print this page

hager REQ5 X Series Manual page 4

Door station video 2-wire

Advertisement

Calling up and changing of system settings
On the back of the video insert, there are 3
operating buttons and a 2-digit 7-segment display
(Figure 2, 8 - 11).
 Press
/
button.
Device turns to setting mode. The fi rst menu
entry
is displayed.
The reading directions of the 7-segment display
P
varies by 180° depending on which button
you start with.
 Select the desired menu entry with
(fi gure 10).
 Confi rm the selection with
The 7 segments display goes dark if there is no
P
actuation for 5 seconds. Settings are applied.
The device returns to normal operation.
Setting the values
The menu entry to be set is confi rmed and fl ashes
alternately with the value to be set.
 Press
/
button.
Short button-press: change the value by one
step.
Long button-press: run through values. Scrol-
ling stops when the button is released.
 Confi rm set value with
.
The device applies the setting and returns to
the previous menu entry.
Address call push-button automatically
The call push-button and connector on the back
are addressed by the automatic call push-button
addressing as follows. The addressing takes place
starting from the top downwards, and with a two-
rowed door station, counterclockwise automatically
upwards to the right (fi gure 11).
Door stations are automatically pre-confi gured
P
at the factory.
The menu entry
is selected.
nately with the entry
for cancel.
 With
/
select the entry
addressing.
 Confi rm with
.
During the addressing, the display fl ickers.
Afterwards the display returns to the previous
menu entry
.
0/0
0/0
0/1
0/1
0/2
0/3
0/4
0/5
0/2
0/6
0/7
Figure 11: Module address and automatic call
push-button addressing
Set individual call push-button address/function
The menu entry
Set individual call push-button
address/function is selected and fl ashes.
 Confi rm the call push-button to be set.
The menu entry
fl ashes alternately with the
current address/function.
 With
/
select the required address
or function
for light push-button,
door release push-button or
4 2
 Confi rm set address/function with
The device applies the setting and returns to
the previous menu entry.
Display saved error codes
Video insert and call-button module errors that
occur during operation are stored in the the error
memory of the video insert for diagnosis.
 Select menu entry
/
confi rm with
If no error code exists
/
seconds and afterwards
If error codes are saved
.
the module address and the error code.
 Press button
codes if necessary.
 Press button
Error
Error cause
code
Communication error
between camera
insert and call push-
button module. Once
the error has occurred
3 times, the system
is reset automatically
and the error code is
generated.
sticking call button
Writing of the call
push-button address
in the call push-button
module fails.
Table 2: Error codes and counter actions
fl ashes alter-
The memory should only be deleted once 5
P
error codes have been stored, so that new error
for automatic
codes can be saved.
Identical error codes are only saved once.
P
0/F
0/E
0/4
0/D
0/C
0/B
0/A
0/3
0/9
0/8
...
for
for no function.
.
.
with button
/
and
is displayed for 2
.
fl ashes followed by
/
, to call up further error
to return to menu entry
.
Counter actions
If the error per-
sists, the call
push-button
module must be
replaced.
Check call push-
button module,
and if there is a
defect, replace
and address.
If the error per-
sists, the call
push-button
module must be
replaced and
addressed.
Inserting door station
The system settings are complete.
 Remove opening tool from housing.
 Insert door station and press down until it clicks
audibly into place simultaneously at the top and
bottom if possible (Figure 12).
Figure 12: Insert door station