MANUAL XCLEAR INDUSTRIAL IMMERSION UV-C

EN
harmonized European standards applicable to the assembled appliance/machine, and in
particular the standards defined in NEN-EN-IEC 60335-2-109:2010.
NEN-EN-IEC 60335-2-109:2010 CLAUSE 22.102
In UV radiation water treatment appliances, no UV radiation shall be discharged from the
*
appliance
before, during or after installation
during operation
during maintenance
during cleaning
during replacement of the UV-C lamp
NOTE This requirement may be met by mechanical construction, or by a switch
energizes the UV-C lamp.
*
Compliance is checked by inspection and by the tests of Clause 32.
It shall not be possible to operate the switch, if any, with test probe B of IEC 61032
**
machine, and in particular the standards defined in NEN-EN-IEC 60335-2-109:2010 and NEN-
EN-IEC 60335-1:2010.
NEN-EN-IEC 60335-2-109:2010 CLAUSE 22.101
Class I UV radiation water treatment appliances having an enclosure of non-metallic material
shall be constructed so that leakage of liquids does not result in a hazard.
Compliance is checked by the following test.
A hole is made in the enclosure.
The appliance is placed in the most unfavourable position that is possible according to the
instructions.
Water containing approximately 1 % NaCI is poured into the enclosure at a rate of
approximately 100 ml/min, avoiding live parts.
The accumulating water shall come into contact with earthed metal before reaching live
parts.
| XCLEAR IMMERSION UV-C MANUAL
6
Please read carefully through these installation
instructions before installing this appliance.
Attention! The Immersion UV-C may not be put into operation until it has been built
into an appliance/machine to a maximum depth of 9 metres or has been assembled
with other appliances/machines to form an appliance/machine that meets the
Attention! The Immersion UV-C may not be put into operation until the
appliance/machine has been fitted with proper earthing that meets the
harmonized European standards applicable to the assembled appliance/
that de-
**

Hide quick links:

Advertisement

loading
Need help?

Need help?

Do you have a question about the Xclear IMMERSION UV-C 40W AMALGAM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Xclear immersion uv-c 80w amalgamXclear immersion uv-c 40wXclear immersion uv-c 75w