Chengdu Ebyte Electronic Technology Co., Ltd
5.40 Read IO1 input
5.41 Set IO2 output
Request:AT+ IO2=[para]
5.42 Set IO3 output
Request:AT+ IO3=[para]
5.43 Read/set PWM0 duty cycle
Request:AT+PWM0?
Set:AT+PWM0=[para]
5.44 Read/Set PWM1 duty cycle
Request:AT+PWM1?
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd
Command
Request:AT+ IO1?
Description: Be effective at once
Command
1.Be effective at once, save when power off
2.IO Keep setting level after next power-on
Command
1. Be effective at once, save when power off.
2.IO Keep setting level after next power-on
Command
Description: Be effective at once, save when power off.
Command
Respond
+OK=[para]
Respond
+OK:success
+ERR=[NUM]:error
Description:
Respond
+OK:success
+ERR=[NUM]:error
Description:
Respond
+OK=[para]
+OK:success
+ERR=[NUM]:error
Respond
+OK=[para]
E104-BT05 User Manual
Parameter
Para: 0,1 ASCII
0:low level
1:High level
Parameter
Para: 0,1 ASCII
1:high level
0:low level
Parameter
Para: 0,1 ASCII
1:High level
0:Low level
Parameter
Para: 0~100% ASCII
0 close PWM
Parameter
Para: 0~100% ASCII
22