Chengdu Ebyte Electronic Technology Co., Ltd
5.23 Read MAC binding status, turn MAC binding on and off
Command
Request:AT+BOND?
Set:AT+BOND=[para]
5.24 MAC Read/Set bonded MAC address
Request:AT+BONDMAC?
Set:AT+BONDMAC=[para]
5.25 Request/Set MTU length
Request:AT+MTU?
Set:AT+MTU=[para]
5.26 Request/Set transparent transmission service UUID length
Request:AT+UUIDTYPE?
Set:AT+UUIDTYPE=[para1]
5.27 Request/ Set Bluetooth service UUID
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd
Description: Be effective at once
Description: Be effective at once, save when power-off
Command
Description: be effective at once, save when power-off
For example, set the bound MAC to "313233343536": AT+BONDMAC=123456
(123456 is ASCII, convert to hexadecimal is: 313233343536)
Command
Description: Restart takes effect, save when power-off
Command
Description : Reconnection takes effect, save when power-off
Command
Respond
+OK=[para]
+OK:success
+ERR=[NUM]:error
Respond
+OK=[para]
+OK:success
+ERR=[NUM]:error
Respond
+OK=[para]
+OK:success
+ERR=[NUM]:error
Respond
+OK=[para1]
+OK:success
+ERR=[NUM]:error
Respond
E104-BT05 User Manual
Parameter
Para:0,1 ASCII
0:Bind off
1:Bind on
Parameter
Para:MAC address HEX
Example:F0E1D2C3B4A5
Parameter
Para: ASCII
0:1 stop bit
1:2 stop bit
Parameter
Para1: 0、1 ASCII
0:2-byte UUID
1:16-byte UUID
Parameter
18