Troubleshooting - Bardiani Valvole BBZO Instruction, Use And Maintenance Manual

Single seat tank bottom valve
Table of Contents

Advertisement

7

Troubleshooting

7 Troubleshooting
PROBLEM
External leak
Leaks inside the closed valve
caused by normal wear
External leak
Premature leaks inside the
closed valve
Difficulty opening and closing
EN-IST-BBZO-0420
POSSIBLE CAUSE
Worn gasket
Excessive pressure
Excessive temperature
Aggressive fluids
Too many commands active
Incorrect type of elastomer used
for the gaskets
Incorrect positioning of the
actuator
Incorrect operation of the
actuator
Impurities in the actuator
Incorrect valve body positioning
POSSIBLE SOLUTION
Replace the seal
Replace with a gasket of a
different type of elastomer
Modify the operating conditions
Replace with a gasket of a
different type of elastomer
Install the actuator correctly
Change from normally open
(NO) to normally closed (NC) or
vice versa
Actuator inspection and
maintenance
Disassemble and correctly
reposition the valve body
17