Through-The-Wall Installation - Whirlpool ACM 152XE0 Installation & User Manual

Whirlpool room air conditioner installation & user's guide
Table of Contents

Advertisement

24. Attach the front panel. Remove the 2
front panel screws from unit base.
Replace front panel by pushing it straight
on and then lowering it slightly to lock it
in place. Attach bottom front of panel by
reinserting the 2 front panel screws.
Through-the-wall
installation
It is the consumer's
responsibility
and
obligation to have this product installed
by a qualified technician who is familiar
with through-the-wall
room air conditioner
installations.
1. Cut an opening
through
the wail. Re-
move any insulation and keep for Step 8.
2. Measure depth of wail opening
and
construct
finish frame. Use 1" (25 mm)
or heavier lumber for wood frame con-
struction. When using a wood, metal, or
plastic molding, the finish frame should
line up with the inside wall. If a plastered
wall is to be flush with the cabinet, and no
molding is used, the finish frame must be
set %" (13 mm) back from the finished
plaster surface. See illustrations
at right
for frame construction
and brick veneer
construction
information.
Finish frame measurements
include:
A - Wall opening width
B - Wall opening height
C - Depends on wall thickness and
type of molding
NOTE: Apply wood preservative
to the
surface exposed to the outside.
continued
on next page
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acm184xe0Acm244xe0

Table of Contents