Siemens ULTRAMAT 6 Manual page 134

Hide thumbs Also See for ULTRAMAT 6:
Table of Contents

Advertisement

Available languages

Available languages

7.5.9
Function Block AI 4
Class
Sl
Index
Ind
Elem
Default
ot
abs
ex
ent
Value
rel
BLOCK
4
16
0
1
250
2
2
3
1
4
1
5
0
6
0
7
0x4001
8
0x0300
9
0
10
45
11
0x0441
12
1
STD
17
1
0
STD
18
2
Compone
nt 4
STD
19
3
0
STD
20
4
0
STD
21
5
0x08
STD
22
6
1
0x08
2
0x98
3
0x08
STD
23
7
1
0x0000
2
0x0000
3
0x0000
4
0x0000
STD
24
8
1
2
3
4
MAND
26
10
1
0
2
0x4F
MAND
27
11
1
100.0
2
0.0
MAND
28
12
1
100.0
2
0.0
3
4
MAND
29
13
0
MAND
30
14
0x0409
MAND
32
16
0.0
ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61
Schnittstelle PROFIBUS DP / PA Interface
A5E00054148-03
Function Block AI 4
Object
BLOCK_OBJECT
Reserved
Block Object
Parent Class
Class
DD-Reference
DD-Revision
Profile
Profile Revision
Execution Time
NumberOfParameters
Address of VIEW 1
Number of View Lists
ST_REV
TAG_DESC
STRATEGY
ALERT_KEY
TARGET_MODE
MODE_BLK
Actual
Permitted
Normal
ALARM_SUM
Current_Alarm
Unacknowledged
Unreported
Disabled
BATCH
BATCH_ID
RUP
OPERATION
PHASE
OUT
Value
Status
PV_SCALE
EU100
EU0
OUT_SCALE
EU100
EU0
UNIT
Dec_Point
LIN_TYPE
CHANNEL
PV_FTIME
(Analog Input)
Parameter description
Block characteristic
250 = not used
Block-Typ (Function)
Parent class: 01 = Input
01 = Analog Input
reserved
reserved
PA-profil-number assigned by PNO for
PROFIBUS - PA = 64
Profile 3.0
f0r future use
number of parameters
Index of view 1
Number of views
Identification / device / statistic rev.-no. /
Function Block: counter which is incremented
at any change of configuration parameters
Unique tag in the system which can be used
by the user
Strategy
User can write value for alert handling
Target mode of block = Auto
Set block mode
Actual mode
Permitted modes: Auto, O/S, MAN
Set mode in normal operation
Alarm status
Current Alarm
Not acknowledged
Not reported
Disabled
Stored information for batch processes
Batch identification
Equipment
Operation
Phase
Output value: measured value in select output
mode, unit is set in output scale
Output value
Quality
Input / measured value scale
Input / measured value scale / fullscale value /
corresponding unit is set in output scale
Input / measured value scale / initiale value /
corresponding unit is set in output scale
Output / output scale
Output / output scale / fullscale value
Output / output scale / initiale value
Output / output scale / physical unit
Decimal digits of output value
Linearization type
Channel number: number of transducer block
and relative index
Output / filter time constant in seconds
Data Type
Num
Store
cy
ber
(acc. to
cli
profile)
c
ds32
1
C
unsigned16
1
N
visible_string
32
S
unsigned16
1
S
unsigned8
1
S
unsigned8
1
S
ds37
1
D
ds42
1
D
ds67
1
S
ds33
1
D
x
float
2
S
ds36
1
S
unsigned8
1
S
unsigned16
1
S
float
1
S
re
wri
ad
te
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
134

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents