Removing Power Head Assembly
Manually remove the Power Head Assembly:
Press and hold Manual Button
With 8 hex key, insert Cam Hole, turn the Cam anti-clockwise to the marked position
Remove the Connector
Remove the Locking Bar
Pull the Power Head Assembly outwards.
Automatic remove the Power Head Assembly:
Unlock the screen
Press and hold Down button, the valve will advance the Cam to the marked position
Remove the Connector
Remove the Locking Bar
Pull the Power Head Assembly outwards.