Automatic Calculate mode contains advanced system settings.
In Regen Mode you can select four different regeneration modes. The system should be set
to Meter Delayed for proper operation.
Calendar Clock: the unit will initiate regeneration at the next pre-set regeneration time
based on the interval of days between regeneration days.
Meter Immediate: the unit will initiate regeneration immediately after the volume remain-
ing reaches zero.
Meter Delayed: this is the most common setting. When the volume remaining reaches
zero, the system will initiate regeneration at the next preset regeneration time.
Meter Override: when the volume remaining reaches zero, the system will initiate regen-
eration at the next pre-set regeneration time. If the days between regeneration are reached
before the volume remaining reaches zero, the system will override the meter setting and
initiate regeneration.