Page 1
165 HIM Series Softener Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant to all seals. Rev 8, December 28 2011...
TABLE OF CONTENTS Water Softener Gallon Setting Chart ........................3 Specifications ................................. 4 Programming ................................5 General Valve Installation ............................7 Start-up Instructions .............................. 8 System Configuration ............................. 9 Maintenance ................................ 10 Power Head Valve Exploded View ........................12 Power Head Parts List ............................13 Control Valve Exploded View ..........................
Water Softener Gallon Setting Chart Water Softener Gallon Setting Chart Instructions: First select the chart for your model of water softener, then simply line up the number of people living in the home with the hardness of the water and select the appropriate gallon setting for your model. at 15lbs salt/CF .75 CF Total Hardness in Grains per US Gallon...
Figure 3. Valve Display System Initialization When power is supplied to the control, the screen will display TIME OF DAY AND DEFAULT GALLON SETTING. If the valve is not in service it will read “CANATURE” while the valve returns to the service position.
Programming 1. Press ‘ ’ to enter programming. If the system has been inactive, you may have to hold and press ‘ ’ until you hear a beep to unlock the display screen. Press ‘ ’ or ‘ ’ to select which setting to modify. 2.
Page 6
Program Options Depending on the current option settings, some parameters cannot be viewed or set. Program Mode DESCRIPTION PARAMETER OPTIONS This option controls whether cubic meters or US gallons is used for the volume display and the format REGIONAL METRIC of the day, year, and month.
General Valve Installation Water Pressure Minimum 25 PSI Electrical Supply Uninterrupted 115V AC Existing Plumbing Free of any deposits or build-ups inside pipes. Softener Location Locate close to drain and connect according to plumbing codes Bypass Valves Always provide for bypass valve if unit is not equipped with one.
2. When power is supplied to the control, the screen will display TIME OF DAY AND DEFAULT GALLON SETTING. If the valve is not in service it will read “CANATURE” while the valve returns to the service position. 3. If the system has been inactive, you may have to hold and press ‘ ’ until you hear a beep to unlock the display screen. Press “...
System Configuration SYSTEM CAPACITY (GRAINS) CYCLE TIME (MINUTES) REFILL TIME (MINUTES) @ 0.70 GPM BLFC @ 15 lbs/cu ft @ 15 lbs/cu ft RESIN VOLUME (Factory @ 10 lbs/cu ft @ 6 lbs/cu ft @ 3 lbs/cu ft (Factory @ 10 lbs/cu ft @ 6 lbs/cu ft @ 3 lbs/cu ft Setting) BACKWASH BRINE/RINSE RINSE...
Figure 10. Bypass Installation View Manual Bypass In the case of emergency, such as an overflowing brine tank, you can isolate your water softener from the water supply using the bypass valve located at the back of the control. In normal operation the bypass is open with the on/off knobs in line with the inlet and outlet pipes.
Page 11
Figure 11 Injector Assembly Cleaning the Injector Assembly Sediment, salt and silt will restrict or clog the injector. A clean water supply and pure salt will prevent this from happening. The injector assembly is located on the right side of the control valve. This assembly is easy to clean. Shut off the water supply to your softener and reduce the pressure by opening a cold soft water faucet.
Power Head Parts List Item No. Part No. Part Description Quantity 5056136 Screw-ST3.5×13(Hexagon with Washer) 5056014 Bnt65 Back Cover 5010045 Piston Stem Holder 13000426 Screw-ST2.9×13(Large Wafer) 5056139 Washer-3x13 5056005 Main Gear 5056083 Screw-M4x14 5056166 Screw-ST4.2×12(Large Wafer) 5056141 Washer-4x12 13111004 Washer-4x9 5056016 Refill Regulator 5056015...
Control Valve Parts List I t em N o. P art N o. P art D i scri pt i on Q uant i t y A 01 05056087 S crew -M 5× 12(H exagon) A 02 05056088 S crew -M 5× 16(H exagon w i t h W asher) A 03 05056047 E nd P l ug R et ai ner...
Trouble Shooting Issue Possible Cause Possible Solution A. Unit fails to initiate a 1. No power supply. Check electrical service, fuse, etc. regeneration cycle. 2. Defective circuit board. Replace faulty parts. 3. Power failure. Reset time of day. B. Water is hard. 1.
When properly installed and maintained, it will give years of trouble free service. Five Year Complete Parts Guarantee: Canature North America Inc. will replace any part which fails within 60 months from date of manufacture, as indicated by the serial number, provided the failure is due to a defect in material or workmanship.