Advertisement

Precautions
NOTE
This document provides simple and distinctive guidelines for quick hardware installation of the
NE05E&NE08E(NE05E-S2/SE/SF/SG/SH/SI/SQ&NE08E-S6/S6E).
Based on the height of a device, the NE05E-S2/SE/SF/SG/SH/SI/SQ are considered 1 U devices, and the
NE08E-S6/S6E are considered 2 U devices. 1 U = 44.45 mm (1.75 in.)
As the installation methods are similar, the fixed NE05E-SI is used as an example for the 1 U device, and the
card-inserted NE08E-S6 is used as an example for the 2 U device. The installation differences are specially
described in this document.
This document does not describe pre-delivery assembly. This document only describes procedures for onsite
installation.
CAUTION
Electrostatic Discharge
Wear ESD gloves or Antistatic Wrist Strap prior to contact
with the equipment or before handling the plug-boards,
boards, and IC chips to prevent damage to sensitive
components caused by electrostatic discharge from the
human body.
CAUTION
Bundling cables
Binding intervals between cable ties or optical fiber binding straps inside the cabinet cannot exceed
250 mm.
CAUTION
Pre-Installation Check
Verify that the equipment room, power supply, ground cables and optical cables are ready for installation.
Start the installation according to the engineering design documents after confirming that conditions are
met. Refer to the Installation Guide for information about specific operational requirements and technical
specifications.