Removing The Nozzle Assembly And The Vane Motor; Removing The Horizontal Vane Motor - Mitsubishi Electric MSZ-FT25VG-E1 Service Manual

Indoor unit
Table of Contents

Advertisement

OPERATING PROCEDURE
3. Removing the nozzle assembly and the vane
motor
<Removing the nozzle assembly>
(1) Remove the panel (Refer to section 1.) and the corner
box.
(2) Remove the V.A. clamp, and then the indoor/outdoor
connecting wire. (Refer to section 2.)
(3) Remove the electrical cover. (Refer to section 2.)
(4) Disconnect the following connectors on the electronic
control P.C. board:
CN151 (Vane motors)
(5) Pull out the drain hose from the nozzle assembly and
remove the nozzle assembly.
4. Removing the vertical vane motor unit
(1) Remove the nozzle assembly. (Refer to section 3.)
(2) Remove the crank of the vertical vane motor from the
arm of the vertical vane.
(3) Remove the screw of the vertical vane motor, and pull
the vertical vane motor.
(4) Remove the crank of the vertical vane motor unit from
the shaft of the vane motor.
(5) Remove the vertical vane motor from the vertical vane
motor unit.
(6) Disconnect the connector of vertical vane motor from
the vertical vane motor.

5. Removing the horizontal vane motor

(1) Cut the fixing band of the vane motor lead wire. (Photo 5)
(2) Remove the screws of the horizontal vane motors and
remove the horizontal vane motors. (Photo 7)
(3) Disconnect the connectors from the horizontal vane
motors.
OBH864
PHOTOS/FIGURES
Photo 5
Fixing band of the vane motor lead wire
Photo 6
Photo 7
Screws of
the horizontal
vane motor
38
Screw of the
vane motor unit
Screws of
the horizontal
vane motor

Hide quick links: