10-3. INSTRUCTION OF TROUBLESHOOTING

1. Check of the unit.

Start

Indoor unit operates.
Outdoor unit does
not operate.
Outdoor unit
Outdoor unit
operates only
does not
in Test Run
operate even
operation.
in Test Run
operation.
Check room
Refer to "How
temperature
to check
thermistor.
inverter/com-
Refer to 10-
pressor".
7. "Test point
diagram and
voltage".
Upper lamp
blink on and off
at 0.5-second
intervals
Cause:
Indoor/Outdoor
unit
• Miswiring or
trouble of serial
signal
Refer to 10-
6. "How to
check mis-
wiring and
serial signal
error".
OBH864
Indoor unit operates.
Outdoor unit does
not operate normally.
Indoor unit
Unit does not
operates, when
operate nor-
EMERGENCY
mal operation
OPERATION
in COOL or
switch is pressed.
HEAT mode.
Refer to
Refer to 10-6.
"Check of R.V.
"Check of remote
coil".
controller and
indoor electronic
control P.C. board".
Upper lamp
Upper lamp
2-time blink
3-time blink
Cause:
Cause:
Indoor unit
Indoor unit
• Trouble
• Trouble of
of room
indoor fan
temperature
motor
/ indoor coil
thermistor
Check room
Refer to 10-
temperature
6. "Check
thermistor
of indoor fan
and indoor
motor".
coil thermis-
tor. Refer to
10-7."Test
point diagram
and voltage".
Indoor unit does
not receive
the signal from
remote controller.
Indoor unit does
not operate, when
EMERGENCY
OPERATION
switch is pressed.
1. Check indoor/outdoor connect-
ing wire.
2. Check if the power is supplied to
indoor unit.
If power supply voltage is detected,
refer to 10-6.
"Check of indoor
P.C. board and indoor fan motor".
If power supply voltage is not
detected, refer to outdoor unit
service manual.
Upper lamp
Upper lamp
4-time blink
5-time blink
Cause:
Cause:
Indoor unit
Outdoor unit
• Trouble
• Outdoor
of indoor
power sys-
unit control
tem abnor-
system
mality
Replace the
Refer to
indoor elec-
"How to
tronic control
check
P.C. board.
inverter/com-
pressor".
25
OPERATION INDICATOR
lamp on indoor unit is
blinking ON and OFF.
"Test Run operation"
means the operation
within 30 minutes after
EMERGENCY OPERA-
TION switch is pressed.
If blinking of OPERATION
INDICATOR lamp cannot be
checked, it can be checked
with failure mode recall
function.
Refer to outdoor unit
service manual.
Upper lamp
Upper lamp
6-time blink
7-time blink
Cause:
Cause:
Outdoor unit
Outdoor unit
• Trouble
• Trouble of
of outdoor
thermistor in
outdoor unit
control
system
Refer to
Replace the
"Check of
inverter P.C.
outdoor ther-
board or
mistors".
the outdoor
electronic
control P.C.
board.
Upper lamp
14-time blink
or more
Cause:
Outdoor unit
• Other ab-
normality
Check "Flow
chart of the
detailed
outdoor unit
failure mode
recall func-
tion."