Ball settle delay
Most paintball loaders will bounce the paintball in the breech. The ball settle delay allows some time
(measured in milliseconds) for the ball to settle in place before firing. If you experience excessive paint
chopping, you should try increasing your ball settle delay.
Solenoid on time (dwell)
When your marker is cycled, the solenoid valve is held open for the solenoid on time. If this setting is too
low, the marker cannot cycle. If this setting is too high, the marker will use too much air. The correct set-
ting for a Cyborg is 8-10ms.
Eye function
Your Cyborg can utilise the beam sensor (eye) in different ways. This setting can be used to select which
way you would like to have the sensor used. The system can use a delayed mode, where if a ball is not
detected in the breech, a shot will be fired after a half second delay. This mode is useful if you are using
a sound activated loader, or if you would like your gun to indicate to you when you are out of paintballs.
Another option is the forced mode. In this mode, the marker will only fire if a ball is detected. However,
the user can force a shot to be fired by holding the trigger until the marker fires.
Auto power off
Your display system and other software uses power when switched on. To conserve power, the system
can power off after a given period of time, this may be adjusted here.
Game timer
Your display system can display either a rate of fire indicator or a game timer. If the game timer is
switched off, the rate of fire indicator will be displayed. The game timer will be started when the user
presses and releases (not hold) the power button (
).
Brightness
Your OLED display system has an adjustable brightness setting. Lower bright-
ness settings conserve battery power.
User profiles
Users who make changes to the default settings can save these settings as
profiles so that they can be reloaded at a later time. There are three different
profile slots available.
To save a profile, enter the save profile setting by holding the trigger. Once in-
side the setting, you can use the scroll button to select the profile slot number you would like to save to.
Once the desired slot is displayed, hold the trigger again, and the software will ask you to confirm (with
the power button) or cancel (with the scroll button).
To load a profile, follow the same steps after entering the load profile setting. Please note that when
loading a profile, the current settings will be replaced by the loaded profile.
Reset to default
The default settings on your software are preset by the factory to give good all round performance from
your Cyborg. If you have made changes to your software, and would like to return your software to fac-
tory default settings, you can use this reset feature.
To reset your software, enter the reset setting by holding the trigger. Once inside the setting, you can
use the scroll button to select the word "yes", hold the trigger again, and the software will ask you to
confirm (with the power button) or cancel (with the scroll button).
Contents